Step 4: Turning on the System
Turning on the Scalable Platform
Connect the appliance to the power source. At power up:
•
Fan speed goes to maximum.
•
LEDs on the Chassis Management Module light up.
•
After 1-60 seconds, fan speed slows down until it reaches the optimum rate for cooling.
•
Chassis Management Module ACT and PWR LEDs show green.
•
Other LEDs turn off.
Turning off the Scalable Platform
1.
Shutdown the SGMs:
•
If the installation wizard (Step 5) has not yet run, release the levers on each SGM to shut
them down
•
If the installation wizard has run, from gclish run:
asg_hard_shutdown -b all
2.
Shutdown the SSMs and CMMs by releasing the levers.
3.
After the LEDs on SGMs, SSMs and CMMs (both Chassis) show a steady blue, unplug the
power cords.