background image

Swarm

™ User Manual 

4/23/2009 11:59 AM

 

 

 

 

 

 

 
 
 
 
 
 

 
 
 
 

USER MANUAL 

 

Snapshot 

OK on Dimmer 

 

Outdoor OK 

 

Sound Activated 

 

DMX512 

 

Master/Slave 

 

Autoswitching 

Transformer 

 

Replaceable Fuse 

 

User Serviceable 

 

Duty Cycle 

 

 

3000 N 29

th

 Ct, Hollywood, FL 33020 U.S.A.  

(800) 762-1084 – (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com

 

 

Содержание SWARM

Страница 1: ...AL Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master Slave Autoswitching Transformer Replaceable Fuse User Serviceable Duty Cycle 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com ...

Страница 2: ...on Chart 8 Setting up a DMX Serial Data Link 9 Master Slave Fixture Linking 9 Mounting 10 Orientation 10 Rigging 10 4 Operating Instructions 11 Navigating the Control Panel 11 Menu Functions 12 Menu Functions 12 Operation 12 Stand Alone Mode Sound Active Auto 12 Master Slave Mode Master Sound Master Auto 12 DMX Mode 13 DMX Channel Values 13 Setting the starting address 14 General Troubleshooting 1...

Страница 3: ...that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixt...

Страница 4: ... 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Never connect the device to a dimmer p...

Страница 5: ... green blue red green blue Adjustable strobe speed with any color combination Control motor direction and speed Built in automated programs via master slave or DMX Built in sound activated programs via master slave or DMX ADDITIONAL FEATURES High power 3W 1 200mA LEDs Additional power output max 12 units 120V DMX Channel Summary CHANNEL FUNCTION 1 Function 2 Run speed 3 Strobe 4 Rotation ...

Страница 6: ...to LED LED Display DMX LED Enter button Sound LED Safety cable eyebolt Microphone Up button Down button Mode button Sound sensitivity adjustment DMX out DMX in Power link out Fuse holder Power in Bracket adjustment knob Bracket DMX indicator flashing segment on display ...

Страница 7: ...aster slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data...

Страница 8: ...onnector on one end and a female XLR connector on the other end CAUTION Do not allow contact between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other 3 PIN TO 5 PIN CONVERSION CHAR...

Страница 9: ...in connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector 3 Then proceed to connect from the output as stated above to the input of the following fixture and so on CHAUVET Certified DMX Data Cables Order Code Description DMX1 5 DMX Cable 1 5m 4 9ft...

Страница 10: ... clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration fuse replacement and routine maintenance Safety cables must always be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted v...

Страница 11: ...he selected menu function To select a menu item press ENTER Use the UP and DOWN buttons to navigate the menu map and menu options Press the ENTER button to access the menu function currently displayed or to enable a menu option To return to the previous option or menu without changing the value press the MODE button Button Function MODE Used to access the menu or to return to a previous menu optio...

Страница 12: ...nob clockwise increases the sensitivity The unit will react to the low frequencies of music via the internal microphone in sound active mode Auto 1 Press the MODE button until is is displayed for automatic mode 2 Press the ENTER button to confirm your selection 3 Adjust the speed as needed from the display Use the UP and DOWN buttons until the desired speed is selected 001 fast 100 slow 4 Press th...

Страница 13: ...ndicator will begin flashing on the display See the drawing on page 6 for the location of the indicator DMX Channel Values CHANNEL VALUE FUNCTION 1 000 009 010 019 020 029 030 039 040 049 050 059 060 069 070 079 080 139 140 199 200 224 225 249 250 255 Function Blackout Red Green Blue Green Blue Red Blue Red Green Red Green Blue Single color chase Multi color chase Automatic fast Automatic slow Sou...

Страница 14: ... Solution s Breaker Fuse keeps blowing Check total load placed on device Chase is too slow Check users manual for speed adjustment Device has no power Check for power on Mains Check device s fuse Fixture is not responding Check DMX settings for correct addressing Check DMX cables Check polarity switch settings Check DMX indicator on LED display segment Fixture is on but there is no movement to the...

Страница 15: ...ld never overlap If they do this will result in erratic operation of the fixtures whose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to ...

Страница 16: ... the parts carefully Clean the external optics at least every 20 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET and request RMA prior to shipping the fixture Be prepared to provide...

Страница 17: ...ion 14W 0 2A max 230V Inrush Power 0 2A 230V Power Output 12 units max 120V 20 units max 230V LIGHT SOURCE LED 3 x 3W 1 200mA 1 Red 1 Green 1 Blue 50 000hrs RANGE Coverage angle 71 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 U...

Отзывы: