Страница 2: ... 7 AC Power 7 Fuse Replacement 7 Power Linking 7 Mounting 8 Orientation 8 Rigging 8 4 Operation 9 Control Panel Operation 9 Menu Map 9 DMX Linking 9 Configuration DMX 9 Starting Address 9 DMX Channel Assignments and Values 9 3 CH 9 Configuration Standalone 10 Custom Mode 10 Sound Active Mode 10 Adjusting Sound Sensitivity 10 Turning Infrared On Off 10 IRC 6 Operation 10 Master Slave Mode 11 5 Main...

Страница 3: ...the product not work cause damage to the product or cause harm to the operator Important installation or configuration information The product may not function correctly if this information is not used Useful information Disclaimer Chauvet believes that the information contained in this manual is accurate in all respects However Chauvet assumes no responsibility and specifically disclaims any and ...

Страница 4: ...he outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots on the product s ...

Страница 5: ...SlimSTRIP UV 18 IRC User Manual Rev 2 Page 5 of 15 2 INTRODUCTION Product Overview DMX In Out Power Out Fuse Holder Safety Loop LED Display IR Sensor Microphone Control Buttons Power In ...

Страница 6: ...Page 6 of 15 SlimSTRIP UV 18 IRC User Manual Rev 2 Product Dimensions 41 9 in 1 064 mm 2 3 in 60 mm 5 in 126 mm 5 in 126 mm ...

Страница 7: ...ect the product from the power outlet before replacing the fuse Fuse Replacement 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 2 Pry the fuse holder out of the housing 3 Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating 4 Insert the fuse holder back in place and reconnect power Power Linking The product provides power link...

Страница 8: ... s weight See the Technical Specifications for weight information When mounting the product overhead always use a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multiple products mount the products close enough for power linking cables to ...

Страница 9: ...MX is in the CHAUVET DMX Primer which is available from the Chauvet website http www chauvetlighting com downloads DMX_Primer_rev05_WO pdf Configuration DMX Set the product in DMX mode to control with a DMX controller 1 Connect the product to a suitable power outlet 2 Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product Starting Address When selectin...

Страница 10: ...e do the following 1 Press MENU repeatedly until SenS shows on the display 2 Press ENTER and u 0 u100 will show on the display 3 Turn the music on and adjust the sound sensitivity using the UP and DOWN buttons until the product starts responding to the beat of the music 4 Press ENTER Turning Infrared On Off To enable the Infrared option do the following 1 Press MENU repeatedly until SET shows on t...

Страница 11: ... Press ENTER and d 0 d512 will show on the display 3 Use UP or DOWN to select the starting address 4 Set the DMX address to 001 5 Connect the DMX input of the first slave unit to the DMX output of the master unit 6 Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit 7 Finish setting and connecting all the slave units Master unit 8 Set the master unit to...

Страница 12: ...ncy To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free...

Страница 13: ...51 W 50 W Operating Current 0 4 A 0 2 A Power linking current units 8 A 17 units 8 A 34 units Fuse T2 A 250 V T2 A 250 V Power I O U S Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison U S Local plug Light Source Type Power Lifespan LED 3 W 50 000 hours Color Quantity Current UV 18 700 mA Photometrics Parameter Coverage angle 160 Strobe Rate...

Страница 14: ... shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return You must send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet will refuse any product returned without an RMA number Write the RMA number on a ...

Страница 15: ...g eu World Wide Web www chauvetlighting eu General Information Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO General Information Address Av de las Partidas 34 3B Zona Industrial Lerma Lerma Mexico C P 52000 Voice 52 728 285...