background image

 
 
 
 
 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

User Manual

 

Содержание SHOKER PANEL 180 USB

Страница 1: ...User Manual ...

Страница 2: ...Operation 9 Menu Map 9 DMX Linking 10 Configuration DMX 10 D Fi USB Connectivity 10 Configuration D Fi USB 10 DMX Personality and Starting Address 11 DMX Channel Assignments and Values 11 8 CH 11 5 CH 12 2 CH 12 Shocker Panel 180 Zones for DMX Control 12 Configuration Standalone 13 Automatic Programs 13 Sound Active Mode 13 Custom Mode 13 Auto Program Speed 13 Sound Sensitivity 13 Temperature 13 I...

Страница 3: ...s to be followed ENTER A key to be pressed on the product s control panel ON A value to be entered or selected Symbols Symbol Meaning Electrical warning Not following these instructions may cause electrical damage to the product accessories or the user Critical installation configuration or operation information Not following these instructions may make the product not work cause damage to the pro...

Страница 4: ...e sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventila...

Страница 5: ...NG DO NOT plug anything other than a D Fi USB into the USB port Doing so may cause damage to the product Bracket Adjustment Knob Mounting Brackets LCD Display Power In Microphone Power Out Fuse holder D Fi USB Port DMX In DMX Out Menu Buttons Safety Loop IR Sensor Front View Back Panel View ...

Страница 6: ...Page 6 of 19 Shocker Panel 180 USB User Manual Rev 1 Product Dimensions 7 8 in 198 mm 2 25 in 57 mm 8 8 in 223 mm ...

Страница 7: ... rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 2 Pry the fuse holder out of the housing 3 Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating 4 Insert the fuse holder back in place and reconnect power Disconnect the product from the power outlet bef...

Страница 8: ...chnical Specifications for weight information When mounting the product overhead always use a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multiple products mount the products close enough for power linking cables to reach The bracket ad...

Страница 9: ...l up the list of options or to find a higher value DOWN Press to scroll down the list of options or to find a lower value ENTER Press to activate a menu option or a selected value Menu Map Mode Programming Steps Description 2 CH d 1 d512 2 channel DMX mode 5 CH 5 channel DMX mode 8 CH 8 channel DMX mode P P 1 P 8 Auto program S S 1 S100 Program speed U d 0 d255 Custom mode sets dimmer S 0 S255 Cus...

Страница 10: ...mply set the product s DMX Personality and DMX Address set the DIP switch D Fi receiving transmitting channel then plug it into the D Fi USB port WARNING DO NOT plug anything other than a D Fi USB into the USB port Doing so may cause damage to the product Once plugged in the D Fi USB will take over the product Wired DMX manual display control menu buttons and IRC will be unavailable until you unpl...

Страница 11: ...e Percent Setting 1 Zone 1 000ó005 No function 006ó249 Strobe rate slow to fast 250ó255 Continuous on blinder effect 2 Zone 2 000ó005 No function 006ó249 Strobe rate slow to fast 250ó255 Continuous on blinder effect 3 Zone 3 000ó005 No function 006ó249 Strobe rate slow to fast 250ó255 Continuous on blinder effect 4 Zone 4 000ó005 No function 006ó249 Strobe rate slow to fast 250ó255 Continuous on b...

Страница 12: ... function 006ó042 Ramp up 043ó085 Ramp down 086ó128 Ramp up ramp down 129ó171 Random 172ó214 Lightning 215ó255 Spikes 5 Zone Strobe Macros 000ó005 No function 006ó042 Macro 1 slow to fast 043ó085 Macro 2 slow to fast 086ó128 Macro 3 slow to fast 129ó171 Macro 4 slow to fast 172ó214 Macro 5 slow to fast 215ó255 Macro 6 slow to fast 2 CH Channel Function Value Percent Setting 1 Strobe Speed 000ó001 ...

Страница 13: ...to low frequencies of music bass and drums Custom Mode To custom mix a static color follow the instructions below 1 Press MENU repeatedly until U shows on the display 2 Press ENTER and dxxx will show on the display 3 Use UP and DOWN to increase or decrease the dimmer value 4 Press ENTER and Sxxx will show on the display 5 Use UP and DOWN to increase or decrease the strobe speed Auto Program Speed ...

Страница 14: ... speed of the program Sound Active Mode Sound Active mode will enable the product to respond to the music To turn on Sound Active mode 1 Press SOUND on the IRC 2 Press or toselect Snd1 or Snd2 To adjust sound sensitivity in Sound Active mode 1 Press SENSITIVITY on the IRC 2 Press or to either increase or decrease sound sensitivity Manual Strobe Control To adjust the dimmer level 1 Press MANUAL on ...

Страница 15: ...s from the master Do not connect more than 31 slaves to the master Master Slave Mode D Fi USB The D Fi USB allows a single Shocker Panel 180 USB product the master to control the actions of one or more Shocker Panel 180 USB products the slaves without the need of a DMX controller or DMX cables The master transmitter product will be set to operate in either Automatic or Sound Active mode while the ...

Страница 16: ...ency To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint fre...

Страница 17: ...wer linking current products 8 A 13 products 8 A 24 products Fuse T 3 15 A 250 V T 3 15 A 250 V Power I O U S Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison U S Local plug Light Source Type Power Lifespan SMD LED 0 5 W 50 000 hours Color Quantity Current Cool white 180 644 mA Photometrics Parameter Strobe Rate 0 to 29 Hz Beam Angle 65 Fie...

Страница 18: ...Technical Support office and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return Send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet w...

Страница 19: ...x 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO Chauvet Mexico General Information Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexico C P 52000 Voice 52 728 285 5000 Technical Support Email servicio chauvet com mx World Wide Web www chauvet com mx CHAUVET EUROPE Chauvet Europe BVBA General Information Address Stokstraa...

Отзывы: