www.chauvetlighting.com 

2006-05-17/13:25 

 

 

Q-Spot

 575

 

USER MANUAL 

Содержание Q-Spot 575

Страница 1: ...CHAUVET 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 05 17 13 25 Q Spot 575 USER MANUAL ...

Страница 2: ...TIONS 9 CONTROL PANEL 9 CONTROL PANEL FUNCTIONS 9 APPLYING CHANGES TO FUNCTIONS QUICK INSTRUCTIONS 9 OPERATING MODES 10 Master Stand Alone 10 Setting Slave Fixtures 10 DMX Mode 10 Daisy Chain Connection 10 DMX 512 addressing 11 Setting the starting address 11 User Configurations 11 Pan Invert Tilt Invert 11 Color Wheel split colors 11 Service Functions 11 Fixture Reset all motors 11 APPENDIX 12 DM...

Страница 3: ... fixtures must be connected to circuits with a suitable Earth Ground Safety Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel o...

Страница 4: ...heel spin in both directions at variable speeds Rotating gobos 6 interchangeable rotating plus open 3 metal 3 dichroic installed Additional gobos 1 dichroic 4 metal Rotating gobo wheel spin in both directions at variable speeds Motorized focus Variable strobe shutter Mechanical dimmer 0 100 Features Automatic Pan Tilt correction Micro stepping motors LED display Display auto off Thermal switch Fan...

Страница 5: ...Power AC input IEC 60320 C14 and fuse holder UP Steps forward through menu functions ENTER Confirms selected menu function 1 1 Moving yoke arm 2 Projector head 3 Base 4 Carrying handle 5 Fan 7 LED display 8 Enter button 9 Choose button 10 Up button 11 Down button 12 DMX output 13 DMX input 14 Carrying handle 15 AC input IEC socket 16 Fuse holder 17 Power switch 2 3 4 5 12 13 14 15 16 17 7 8 9 10 1...

Страница 6: ...luded Do not touch the envelope glass area of the bulb with bare hands If this happens clean the lamp with alcohol and wipe it with a lint free cloth before installation Lamp Installation 1 Unscrew S1 to detach the top cover 2 Unscrew S2 to remove lamp cover and expose lamp compartment 3 If installing a new lamp loosen both screws on the double ended lamp to allow for the lamp to slide into the la...

Страница 7: ...run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground POWER CABLE PIN INTERNATIONAL BROWN Live L BLUE Neutral N YELLOW GREEN Earth EG Ground OPERATING V...

Страница 8: ...o calculating working load limits installation material being used and periodic safety inspection of all installation material and the projector If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The projector should be installed out of the reach of pe...

Страница 9: ... 2 when floor positioned Slave Mode Music Program 1 when mounted upside down Music Program 2 when floor positioned LAMP ON OFF Lamp on Lamp off VEr 1 X Software version HEAt Status Too hot to strike or no lamp LA Er Status Lamp error Applying changes to Functions Quick Instructions Unless other wise stated changes in the control panel can be applied in the following manner 1 Press MODE button repe...

Страница 10: ...hen fixture is floor positioned Setting Slave Fixtures The Master Slave mode will allow you to link multiple units in a daisy chain fashion In this mode the first unit in the daisy chain the master will automatically command all other units following The first unit will operate in a Stand Alone mode and all units following will synchronize to the first unit MENU SET TO NOTES RUN SLAE Slave mode Yo...

Страница 11: ...rease values until the desired value is achieved 4 Press the Enter button to activate selection User Configurations Pan Invert Tilt Invert It is possible to invert the pan and tilt head movement from within the fixture itself This could be helpful in situations where the positioning or rigging of a fixture led to a reverse orientation of the fixture in relation to all or most other fixtures instal...

Страница 12: ...ne fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while p...

Страница 13: ...heel Linear White Open White Blue Blue Blue Orange Orange Orange Quad Yellow Green Sky Blue Orange Quad UV UV UV Rose Red Rose Red Rose Red Red Red Red Orange Sky Blue Orange Sky Blue Orange Sky Blue Yellow Yellow Yellow Pink Pink Pink Green Green Green White Rainbow effect Fast Slow clockwise 000 007 008 019 020 031 032 043 044 055 056 067 068 079 080 091 092 103 104 115 116 127 128 255 Color Whe...

Страница 14: ...Gobo Bounce Gobo 6 Slow Fast Gobo Bounce Gobo 7 Slow Fast Gobo Bounce Gobo 8 Slow Fast Gobo Bounce Gobo 9 Slow Fast Gobo Scroll Slow Fast 11 000 029 030 059 060 089 090 119 120 149 150 179 180 209 210 255 Rotating Gobo Open White Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo Scroll Slow Fast 12 000 060 061 158 159 255 Gobo Rotation Gobo progressive rotation 0 540 Clockwise rotation Slow Fast Coun...

Страница 15: ...n which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the origina...

Страница 16: ...sible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor movement...

Страница 17: ... mm Image diameter 22 5 mm Maximum thickness 3 mm Static gobo max thickness 2 mm THERMAL Maximum ambient temperature 45 113 F FUSE Main 115V 20mm Glass 15A Fast Blow Main 230V 20mm Glass 6 3A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels Q SPOT57...