Страница 1: ...CHAUVET 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 09 29 19 19 LED PAR83 COLORsplash JR USER MANUAL ...

Страница 2: ...DUCT OVERVIEW 5 SETUP 6 POWER 6 MOUNTING 6 OPERATING INSTRUCTIONS 7 MASTER SLAVE STAND ALONE MODE 7 Daisy Chain Connection 7 Built in Program Options 7 Manual Control Options 8 DMX CONTROL MODE 8 Setting the DMX address 8 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 RETURNS PROCEDURE 11 CLAIMS 11 DMX DIPSWITCH QUICK REFERENCE CHART 12 TECHNICAL SPECIFICATIONS 13 TECHNICAL SUP...

Страница 3: ...ructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fi...

Страница 4: ...Features CONTROL FEATURES 4 channel DMX 512 LED par can Blackout Dimmer Strobe Individual control of Red Green and Blue leds FEATURES 86 LEDs per surface Red 44 Green 21 and Blue 21 Ultra bright LEDs RGB color mixing Built in color change programs Low power consumption Up to 100 000 hour LED life span Master Slave mode OPTIONS Programmable Any universal DMX 512 controller DMX Channel Summary ...

Страница 5: ...al 5 2005 09 29 19 19 DMX dipswitches DMX channel addressing DMX Connectors Fuse Power connection Hanging yoke Power link Red Red Red Red Red Green Blue Green Blue Green Blue Green Blue AC Voltage Switch Product Overview ...

Страница 6: ... rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATIONAL BROWN Live L BLUE Neutral N YELLOW GREEN Earth EG Ground ...

Страница 7: ... individually allowing the creation of an unlimited range of colors The COLORsplash JR can operate in Stand Alone Master Slave and via DMX 512 control utilizing 4 channels Master Slave Stand Alone Mode The Master Slave mode will allow you to link up to as many units you want in a daisy chain fashion In this mode the first unit in the daisy chain will automatically command all other units following...

Страница 8: ...dependently The COLORsplash JR uses 4 channels of control 1 Enable DMX control by setting dipswitch 10 to the ON position Use dipswitches 1 through 9 to address each fixture accordingly Setting the DMX address This DMX mode enables the use of a universal DMX controller device Each fixture requires a start address from 1 to 511 A fixture requiring one or more channels for control begins to read the...

Страница 9: ...ssible from the selected start address until zero is achieved EXAMPLE STARTING ADDRESS Address 10 Pin 4 8 Pin 2 2 Total 10 Address 24 Pin 5 16 Pin 4 8 Total 24 Resolving address using simple math Address 233 233 128 105 Turn ON Dip 8 105 64 41 Turn ON Dip 7 41 32 9 Turn ON Dip 6 9 8 1 Turn ON Dip 4 1 1 0 Turn ON Dip 1 You will most likely use the first available number which maybe number 1 This nu...

Страница 10: ...of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whi...

Страница 11: ... and a brief description of the cause for the return Be sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Claims Damage incurred in shipping is the responsibility o...

Страница 12: ...332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 11...

Страница 13: ... FUSE Main 20mm Glass 1A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 4 ORDERING INFORMATION COLORsplash JR LED PAR83 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting com Telephone...