Chauvet COLORrail Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

User Manual 

Содержание COLORrail

Страница 1: ...User Manual ...

Страница 2: ...WER 7 Power Linking 7 MOUNTING 8 Orientation 8 Rigging 8 4 OPERATING INSTRUCTIONS 9 MENU MAP 9 CONFIGURING THE STARTING ADDRESS 10 DMX Operation 10 Master Slave Mode Sound Active Auto Mode 10 Automatic 11 Program Selection 11 Sound Active 11 Static Color 11 DMX CHANNEL VALUES 12 26 CH Mode 12 14 CH Mode 13 7 CH Mode 14 4 CH Mode 15 3 CH Mode 15 2 CH Mode 15 5 APPENDIX 16 GENERAL TROUBLESHOOTING 16...

Страница 3: ...n from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected I...

Страница 4: ...ect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by u...

Страница 5: ...m angles provided refer to a single section of the COLORrail fixture When calculating the coverage of the product for a specific application consider that the total output of the fixture will not be circular but rather oval shaped This is due to the rectangular design of the fixture ...

Страница 6: ...2 Introduction 6 11 29 2010 4 14 PM Product Overview Control Panel DMX In DMX Out Power Out Power In ...

Страница 7: ...sistor or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via the Edison outlet located in front of the power input cable Please see the diagram below for further explanation The maximum quantity of COLORrail that may be linked is 15 Th...

Страница 8: ...ower link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this When aiming the fixtures you may use the bracket yoke adjustment knob s Loosen the knob s adjust to the desired angle and then tighten the knob s by turning clockwise Do not use tools for this step as it may cause dam...

Страница 9: ...create a custom mix G000 255 B000 255 Program Selection Pr02 20 Pr 02 20 Program selection SP 01 99 FL Program speed low high full Fd 00 99 Fade time FS 00 99 Strobe speed Program Selection Pr01 21 22 These 3 Programs have been listed in a separate section because they have unique options available Pr 01 21 22 Program selection SP 01 99 FL Program speed low high full Fd 00 99 Fade time FS 00 99 St...

Страница 10: ...e If this is your first time using DMX then it is recommended that you refer to the DMX Primer section in the Appendix of this manual 1 Press MENU until d001 512 appears on the LED screen 2 Using UP and DOWN select the starting address 3 Press ENTER until one of the DMX personalities appears on the LED screen 2 CH 3 CH 4 CH 7 CH 14 CH 26 CH 4 Using UP and DOWN select the desired DMX personality 5 ...

Страница 11: ... the Menu Map for details on the different selections that are available 5 Using UP and DOWN modify each setting at a time Programs 01 21 and 22 have unique options available For this reason they have been listed in a separate section in the Menu Map The available options allow you to select one of 7 preset colors for both the background and the foreground Sound Active This fixture has a preprogra...

Страница 12: ...reen section 2 Dimmer 0 100 19 000 Ù 255 Blue section 6 Dimmer 0 100 7 000 Ù 255 Blue section 2 Dimmer 0 100 20 000 Ù 255 Red section 7 Dimmer 0 100 8 000 Ù 255 Red section 3 Dimmer 0 100 21 000 Ù 255 Green section 7 Dimmer 0 100 9 000 Ù 255 Green section 3 Dimmer 0 100 22 000 Ù 255 Blue section 7 Dimmer 0 100 10 000 Ù 255 Blue section 3 Dimmer 0 100 23 000 Ù 255 Red section 8 Dimmer 0 100 11 000 ...

Страница 13: ... 000 Ù 255 Green section 1 Dimmer 0 100 10 000 Ù 255 Blue section 3 Dimmer 0 100 4 000 Ù 255 Blue section 1 Dimmer 0 100 11 000 Ù 255 Red section 4 Dimmer 0 100 5 000 Ù 255 Red section 2 Dimmer 0 100 12 000 Ù 255 Green section 4 Dimmer 0 100 6 000 Ù 255 Green section 2 Dimmer 0 100 13 000 Ù 255 Blue section 4 Dimmer 0 100 7 000 Ù 255 Blue section 2 Dimmer 0 100 14 000 Ù 000 001 Ù 255 Strobe No Fun...

Страница 14: ...67 168 Ù 175 176 Ù 183 184 Ù 191 192 Ù 199 200 Ù 207 208 Ù 215 216 Ù 223 224 Ù 231 232 Ù 255 Color Macro No Function Red Yellow Green Cyan Blue Purple White Auto Program 1 Auto Program 2 Auto Program 3 Auto Program 4 Auto Program 5 Auto Program 6 Auto Program 7 Auto Program 8 Auto Program 9 Auto Program 10 Auto Program 11 Auto Program 12 Auto Program 13 Auto Program 14 Auto Program 15 Auto Program...

Страница 15: ...0 Ù 087 088 Ù 095 096 Ù 103 104 Ù 111 112 Ù 119 120 Ù 127 128 Ù 135 136 Ù 143 144 Ù 151 152 Ù 159 160 Ù 167 168 Ù 175 176 Ù 183 184 Ù 191 192 Ù 199 200 Ù 207 208 Ù 215 216 Ù 223 224 Ù 231 232 Ù 255 Color Macro No Function Red Yellow Green Cyan Blue Purple White Auto Program 1 Auto Program 2 Auto Program 3 Auto Program 4 Auto Program 5 Auto Program 6 Auto Program 7 Auto Program 8 Auto Program 9 Aut...

Страница 16: ...ng Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable Low level signal Install amplifier r...

Страница 17: ...e pin 2 is Data Negative S and pin 3 is Data positive S Fixture Linking Daisy Chain You will need a daisy chain to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a daisy chain determines the number of fixtures the data link can su...

Страница 18: ...o read the data on the channel indicated by the start address For example a fixture that uses six DMX channels and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addresses so that the channels used do not overlap and note the start address selected for future reference If this is your first time addressing a fixture using the DMX co...

Страница 19: ...n 4 Not used Pin 5 Setting up a DMX Daisy Chain 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector 3 Then proceed to connect from the output as stated above to ...

Страница 20: ...0 days Clean the fixture at least every 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be refused Call CHAUV...

Страница 21: ... 320 total 128 red 96 green 96 blue Rating red green blue W 20 mA 100 000 hrs PHOTO OPTIC Lux 770 1 m Beam angle 13 Field angle 20 INDOOR OUTDOOR Rating For indoor use only THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX...

Страница 22: ...0 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 5200 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 Press 4 fax 954 929 5560 Attention Service World Wide Web www chauvetlighting com ...