Maverick Storm 2 Profile User Manual Rev. 1
Maintenance
5. Maintenance
Product Maintenance
Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of
the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean
each lighting product at least twice a month. However, be aware that usage and environmental conditions
could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:
1. Unplug the product from power.
2. Wait until the product is at room temperature.
3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external
surface/vents.
4. Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl
alcohol.
5. Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
6. Softly drag any dirt or grime to the outside of the transparent surface.
7. Gently polish the transparent surfaces until they are free of haze and lint.
Torque Measurements
To maintain the IP rating when reassembling the product, use the given torque measurements for each of
the following screws and bolts:
•
Screws inside feet: 15.3 Kgf.cm, 13.3 lgb.in
•
Base screws around outside (not the feet): 16.3 Kgf.cm, 14.16 lgb.in
•
Base screws in middle: 35.6 Kgf.cm, 90.9 lgb.in
•
Omega bracket holder: 12.2 Kgf.cm, 10.6 lgb.in
•
Front and rear base cover: 25.5 Kgf.cm, 22.1 lgb.in
•
Screws around power and data ports: 3.5 Kgf.cm, 3 lgb.in
•
Fuse: 7.1 Kgf.cm, 6.1 lgb.in
•
Center of yoke plate: 25.5 Kgf.cm, 22.1 lgb.in
•
Arm cover screws: 25.5 Kgf.cm, 22.1 lgb.in
•
Allen Key screws next to front lens: 25.5 Kgf.cm, 22.1 lgb.in
•
Allen Key screws holding in front lens cover: 12.2 Kgf.cm, 10.6 lgb.in
•
Allen Key screws next to heat pipes on the back: 25.5 Kgf.cm, 22.1 lgb.in
•
Allen Key screws head covers: 25.5 Kgf.cm, 22.1 lgb.in
Vacuum Test Measurements
To ensure that the product has been reassembled correctly, use the IP Tester from Chauvet Professional to
check the following data has the given measurements for the given method:
•
Method: Positive
•
Test Pressure (kPa): 2.18
•
Test Duration (seconds): 60
•
PASS State leak pressure (kPa): <0.02
Always dry the transparent surfaces carefully after cleaning them.
Do not spin the cooling fans with compressed air. Damage may result.