Offset Mode (Zero Adjust)

The Offset mode provides fine adjustments for the home position of every moving part in the optical path 

as well as the pan and tilt movements. To adjust these options and prevent borders showing or reduction of 

the light output:

1. From the main level screen, press and hold 

<MENU>

 until the passcode screen appears.

2. Enter the passcode: 

0920

 and press 

<ENTER>

.

3. Select the “zero” position to adjust, from 

PAN

TILT

COLOR

GOBO

GOBO ROTATE

GOBO2

FOCUS-GOBO

FOCUS-GOBO2

ZOOM

PRISM

IRIS

FROST

Light Block

CYAN

MAGENTA

YELLOW

CTO

BLADE1-1

BLADE1-2

BLADE2-1

BLADE2-2

BLADE3-1

BLADE3-2

BLADE4-1

BLADE4-2

BLADE ROTATE

DIMMER1

DIMMER2

MAC4

MAC5

MAC6

RDM ID4

RDM ID5

, or 

RDM ID6

.

4. Adjust the “zero” position for the selected function from 

000–255

.

Web Server

The Maverick Storm 2 Profile Web Server can be accessed by any computer on the same network as the 

product. It allows network access to system information, settings such as control setup, manual testing of 

all functions, firmware updates, and the ability to change the Web Server password.

1. Connect the product to power, and set the 

Control Mode

 to 

ArtNet

 and the 

IP Mode

 to 

Static

.

2. Connect the product to a Windows computer with a network cable.
3. On the computer, set the first value of the IP address of the new network to match the first value of 

the IP address of the product. The IP address of the product is displayed on the 

Home Screen

.

4. Enter the IP address of the product into the URL bar of a web browser on the computer.
5. Enter both the User Name and Password as 

admin

 to log in.

Information

The Information page on the Web Server displays the current settings and the system information of the 

Maverick Storm 2 Profile.

Setup

The Setup page on the Web Server provides options for control, similar to the 

Setup

 menu on the product. 

Click 

Save Settings

 to send the new configuration to the product.

Manual Test

The Manual Test page on the Web Server allows all output functions of the product to be controlled through 

the browser. To set all functions back to default, click 

Reset

.

Firmware Update

The Upgrade page on the Web Server allows the product to be updated with the latest firmware. Go to 

https://www.chauvetprofessional.com

 to download firmware updates.

Security

The Security page on the Web Server gives the option to change the password to the connected product’s 

web server. Enter the old password (

admin

, by default) and the new password twice, then click 

Save 

Settings

 to change the password.

Содержание MAVERICK STOM 2 PROFILE

Страница 1: ...Model ID MAVERICKSTORM2PROFILE User Manual...

Страница 2: ...tent for any other purpose without written consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 29...

Страница 3: ...verview 4 Product Dimensions 5 3 Setup 6 AC Power 6 AC Plug 6 Fuse Replacement 6 Remote Device Management RDM 6 USB Software Update 6 Mounting 7 Orientation 7 Rigging 7 Procedure 7 Signal Connections...

Страница 4: ...9 Display Backlight Timer 19 Fan Mode 20 Dimmer Curve 20 Pulse Width Modulation 20 LED Power 20 Minimum Zoom Focus 20 Preset Selection 20 Preset Synchronization 20 USB Update 21 Reset Function 21 Fact...

Страница 5: ...ust accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the party responsible for compliance could void th...

Страница 6: ...o the surrounding environment before connecting it to power Not for permanent outdoor installation in locations with extreme environmental conditions This includes but is not limited to Exposure to a...

Страница 7: ...not start the product at lower temperatures The minimum ambient temperature is 22 F 30 C Do not operate the product at lower temperatures In the event of a serious operation problem stop using this pr...

Страница 8: ...D yoke profile fixture including CMY CTO color mixing a 4 blade framing shutter system with rotation a color wheel 10 1 zoom a 5 facet prism wheel 1 rotating and 1 static gobo wheel integrated sun shi...

Страница 9: ...Storm 2 Profile User Manual Rev 1 Introduction Product Dimensions 10 12 in 257 mm 14 43 in 366 6 mm 27 52 in 699 mm 18 62 in 473 mm 10 26 in 260 7 mm 15 28 in 388 mm 9 92 in 252 mm 13 7 in 348 mm 4 7...

Страница 10: ...o menu map options USB Software Update The Maverick Storm 2 Profile allows for software update through USB using the built in USB port The product s USB port supports up to 32GB capacity and only work...

Страница 11: ...t the structure onto which the product is being mounted can support the product s weight See the Technical Specifications for weight information When mounting the product overhead always use a safety...

Страница 12: ...a 5 pin DMX connection or a WDMX connection For more information about DMX read the DMX primer at https www chauvetprofessional com wp content uploads 2016 06 DMX_Primer pdf Art Net Connection Art Ne...

Страница 13: ...e Lock Screen option 3 Select NO control panel stays unlocked or YES locks control panel Passcode After being prompted to enter the passcode enter the numbers 0920 Technician Mode The technician mode...

Страница 14: ...N WDMX Pan Reverse NO Normal pan YES Reversed pan Tilt Reverse NO Normal tilt YES Reversed tilt Screen Reverse NO Normal screen display YES Inverted screen display AUTO Automatic display orientation P...

Страница 15: ...WER 64 255 Sets LED power Min Zoom Focus NO Enables disables Min Zoom Focus YES Preset Select PRESET A Recorded preset menu options PRESET B PRESET C Preset Sync NO Transfers recorded preset menu opti...

Страница 16: ...2 2 Blade2 2 Fine Blade3 1 Blade3 1 Fine Blade3 2 Blade3 2 Fine Blade4 1 Blade4 1 Fine Blade4 2 Blade4 2 Fine Blade Rotate Blade Rota Fine Focus Focus Fine Focus Auto Zoom Zoom Fine Prism Prism Rotate...

Страница 17: ...ows speed of each fan in rpm Base Fan1 2 Speed _ _ _ _ Error Information _ _ _ _ _ Shows any errors or No Error Channel Information Frequency 000 255 Shows all current values from input signals Pan Pa...

Страница 18: ...ghest recommended starting address for Dmx Mode 48 CH is 465 Network Setup The Network Setup settings control the IP address subnet mask and universe of the product IP Mode To choose how the IP addres...

Страница 19: ...ntrol 16 bit 5 5 Pan tilt speed 000 255 Fast to slow 6 6 Dimmer 000 255 0 100 7 Fine dimmer 000 255 Fine control 16 bit 7 8 Strobe 000 003 Off 004 007 On 008 076 Synchronized strobe slow to fast 077 1...

Страница 20: ...slow 146 149 Stop 150 231 Counterclockwise rotation slow to fast 232 255 Alternating clockwise counterclockwise rotation short to long 17 Gobo 1 fine rotate 000 255 Fine control 16 bit 16 18 Gobo whee...

Страница 21: ...otation 000 255 0 100 36 Fine blade rotation 000 255 Fine control 16 bit 26 37 Focus 000 255 0 100 38 Fine focus 000 255 Fine control 16 bit 39 Auto focus 000 010 No function 011 030 0 5 meters 031 05...

Страница 22: ...gobo wheels 048 055 Blackout during pan tilt color wheel gobo wheels 056 095 No function 096 103 Pan reset 104 111 Tilt reset 112 119 Color wheel reset 120 127 Gobo wheels reset 128 135 No function 13...

Страница 23: ...the Settings main level 2 Select the Tilt Angle option 3 Select from 270 260 180 180 or 090 90 Black out on Movement To set the product to black out while the pan tilt color wheel or gobo wheels are...

Страница 24: ...control or YES focus adjusts depending on zoom setting Preset Selection To select a preset configuration of menu options 1 Go to the Settings main level 2 Select the Preset Select option 3 Select from...

Страница 25: ...nction of the Maverick Storm 2 Profile 1 Go to the Test main level 2 Select the Manual Test option 3 Select a function to test from Pan Pan Fine Tilt Tilt Fine P T Speed Dimmer Dimmer Fine Shutter Vir...

Страница 26: ...to ArtNet and the IP Mode to Static 2 Connect the product to a Windows computer with a network cable 3 On the computer set the first value of the IP address of the new network to match the first valu...

Страница 27: ...tion Gobo Wheel Gobo Description 1 1 Pipes Poles 2 1 Dots 2 Cookie Cutter 2 Paperclip Party 3 This Way 3 Orbital 4 Fast Moves 4 Dirty Dirt 5 Laser Rays 5 Box Cutter 6 Limbo 6 Crazy Turns 7 Fractured M...

Страница 28: ...utlet 2 Open the head cover by loosening the screws on the top cover 3 Separate the gobo holder away from the gobo wheel by pushing it toward the front of the moving head direction 1 in the diagram Be...

Страница 29: ...rque Measurements To maintain the IP rating when reassembling the product use the given torque measurements for each of the following screws and bolts Screws inside feet 15 3 Kgf cm 13 3 lgb in Base s...

Страница 30: ...Breaker F15 A 250 V F15 A 250 V F15 A 250 V F15 A 250 V F15 A 250 V Power I O U S Worldwide UK Europe Power Input Connector Seetronic Powerkon A Seetronic Powerkon A Power Cable plug Edison Local plug...

Страница 31: ...ional com Chauvet U K Address Unit 1C Email UKtech chauvetlighting eu Brookhill Road Industrial Estate Pinxton Nottingham UK Website www chauvetprofessional eu NG16 6NT Voice 44 0 1773 511115 Fax 44 0...

Отзывы: