Страница 1: ...Operating and Installation Instructions CHARNWOOD DX20i MkII Multifuel Roomheater Bishops Way Newport Isle Of Wight PO3O 5WS U K Tel 01983 537799 Fax 01983 537788 ...

Страница 2: ...table Coal Housecoal doubles trebles or cobbles may all be burnt Do not use singles small nuts or coal dust It is important that large size coal is used i e larger than 50mm or 2 in size The coal should be dry When burning bituminous coal a little extra care is needed Please take note of the section Special Points For Burning Coal Wood Only dry well seasoned wood should be burnt on this appliance ...

Страница 3: ...ignited then load with more fuel close the doors and adjust the thermostat and airwash control to the desired setting Leaving the main doors slightly ajar when lighting will keep the glass clean while the airwash is warming up On initial lighting the fire may smoke and give off an odour as the silicon paint with which the firebox is painted reacts to the heat This is normal and will cease after a ...

Страница 4: ...to the ashpan and should therefore be avoided Clinker should regularly be removed from the firebed After riddling the grate should be put back into the solid fuel or wood position as required the tool should be horizontal for solid fuel or vertical for wood or peat REFUELLING Keep the firebox well filled the fuel may be sloped up from the front firebars but do not allow fuel to spill over the top ...

Страница 5: ...posits on the glass may be burnt off simply by running the fire at a fast rate for a few minutes Do not use abrasive cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure Aerosol spray cleaners should not be used near the appliance whilst it is under fire If the fire is going to be out of use for a long period for instance in the summer then to p...

Страница 6: ...mneys The following points should be noted and with a little care should enable the glass to be kept clean in most situations a The airwash relies on a supply of heated air to keep the glass clean therefore when lighting the stove allow the firebed to become well established before turning the thermostat down This may also be necessary when re fuelling the stove b When re fuelling keep the fuel as...

Страница 7: ...L SQUARE If an existing chimney is to be used it must be swept and checked it must be in good condition free from cracks and blockages and should not have an excessive cross sectional area e g greater than 250mm x 250mm If you find that the chimney is in poor condition then expert advice should be sought regarding the necessity of having the chimney lined If it is found necessary to line the chimn...

Страница 8: ...erall SizesOf Hearth SeeThe Section Titled Hearth Of Hearth 750 mm Surround And Opening Dim A Dim B Max 575mm 22 2 3 Min 555mm 21 3 4 Max 470mm 18 1 2 Min 405mm 16 Theshaded areaon thefaceof thesurround istheminimum flat arearequired 660 mm 265 mm Minimum Fig 4 Limiting Dimensions Fig 5 Limiting Dimensions Of storage cylinder to BS 1566 part 1 should be used in most situations unless the appliance...

Страница 9: ...in any way and that all joints are well sealed Before infilling cover the front of the appliance to protect it Ensure that the flue pipe is central and then fill the space between the body of the appliance and the structural brickwork with vermiculite e g micafil or similar concrete Ensure that there are no air pockets The recommended mix is six volumes of vermiculite granules to one volume of por...

Страница 10: ... lighting check the following points 1 The bottom grate bars must all be fitted and should move freely and easily when the riddling mechanism is operated 2 The plates round the sides and back of the grate must be in position and sitting correctly 3 The throat plate must be fitted in the roof of the appliance COMMISSIONING On completion of the installation and after allowing a suitable period of ti...

Страница 11: ...506 265 405 120 260 200 547 i d 400 260 150 84 604 620 Optional Boiler May BeFitted WithThe1 B S P MaleTappings OnTheLeft Or TheRight CharnwoodDX20i MkII Overall Dimensions Dimensionsarein mm Page 11 HV 7 96 ...