background image

CHARNWOOD

COUNTRY 14B

Roomheater with Boiler

Operating

and

Installation Instructions

C H A R N W O O D

B i s h o p s W a y , N e w p o r t , I s l e o f W i g h t P O 3 0 5 W S , U n i t e d K i n g d o m

T : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 9 9

F : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 8 8

c h a r n w o o d @ a j w e l l s . c o . u k

w w w . c h a r n w o o d . c o m

Содержание Country 14B

Страница 1: ...stallation Instructions C H A R N W O O D B i s h o p s W a y N e w p o r t I s l e o f W i g h t P O 3 0 5 W S U n i t e d K i n g d o m T 4 4 0 1 9 8 3 5 3 7 7 9 9 F 4 4 0 1 9 8 3 5 3 7 7 8 8 c h a r n w o o d a j w e l l s c o u k w w w c h a r n w o o d c o m ...

Страница 2: ...At first you may find it helpful to try several fuels to find the most suitable If you are unable to obtain the fuel you want ask your supplier or an approved fuel distributor to suggest an alternative Use the door opening and ashpan tool to open and close the doors Turn the right hand door knob anti clockwise to open and clockwise to close see Fig 1 Your Charnwood stove is fitted with a multifuel...

Страница 3: ...p The ashpans should be emptied regularly before it becomes too full Never allow the ash to accumulate in the ashpans so that it comes in contact with the underside of the grate as this will seriously damage the grate bars The ashpans are handled using the tool provided Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins To make ash removal easier there i...

Страница 4: ...y the appliance flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush After clearing any soot from within the stove replace the throat plate see Fig 3 the front firebars and side fireplates Different types of sweep s brushes are available to suit different flueways For standard brick chimneys a wire centre sweep s brush fitted with a guide wheel is rec...

Страница 5: ...ed d the fire is not fitted onto a heating system which is too large Do not light the fire if there is any possibility that any parts of the system may be frozen Check that a the fire is burning properly if not then carry out the checks under Fire Will Not Burn Over Firing Freezing Lack of Heat To Radiators Hot Water b the throat plate is fitted correctly see Fig 3 and that it is not distorted c t...

Страница 6: ...himney is in poor condition then expert advice should be sought regarding the necessity of having the chimney lined If it is found necessary to line the chimney then a lining suitable for Solid Fuel must be used If there is no existing chimney then a prefabricated block chimney or a twin walled insulated stainless steel flue to BS 4543 can be used either internally or externally These chimneys mus...

Страница 7: ...e expected Fitting a radiator in the same room as the fire is recommended as it will allow greater flexibility in the way that the system is operated as well as ensuring that there is sufficient heat Connect the heating system to the boiler ensuring that the primary flow pipe rises continuously from the appliance to the vent Fill the system with water and check for leaks The circulating pump may b...

Страница 8: ...ugh the appliance but in most back outlet installations it will be necessary to have a soot door to enable the chimney to be swept This may either be in the actual brickwork of the CONNECTIONS TO FLUES SOOT DOORS chimney or in the register plate Various types and positions of soot doors are shown in figures 8 to 10 Before lighting the fire check the cold setting distance of the thermostat Remove t...

Страница 9: ...of the installation and after allowing a suitable period of time for the fire cement and mortar to dry out the stove should be lit and checked to ensure that smoke and fumes are taken from the appliance up the chimney and emitted safely Also check all joints and seals COMMISSIONING The central heating pump should be adjusted to give the correct water flow against the circuit resistance and the sys...

Страница 10: ... 49 010 BW51 Ash Carrier Optional Extra 14 004 FV15 Secondary Air Rod 50 008 TH02 L Low Level Pipe Stat Opt l Extra 15 002 EW15 Side Fire Plate 51 002 DY18 R H Door Knob Spindle 16 002 BV16 Back Fire Plate 52 002 KV14 Door Catch Cam 17 002 CG01 Bottom Grate Bar 18 002 CG01S14 Set of Grate Bars 14 per set 19 004 FV17L Left Hand Ashpan 20 004 FV17R Right Hand Ashpan 21 004 BV19 Ash Shedding Plate 22...

Страница 11: ... a y N e w p o r t I s l e o f W i g h t P O 3 0 5 W S U n i t e d K i n g d o m T 4 4 0 1 9 8 3 5 3 7 7 9 9 F 4 4 0 1 9 8 3 5 3 7 7 8 8 c h a r n w o o d a j w e l l s c o u k w w w c h a r n w o o d c o m Your Local Charnwood Dealer ...

Отзывы: