background image

INSTALLATION, OPERATION,

 AND SERVICE MANUAL

RO DRINKING WATER SYSTEM

MODEL CWQC50

Содержание CWQC50

Страница 1: ...INSTALLATION OPERATION AND SERVICE MANUAL RO DRINKING WATER SYSTEM MODEL CWQC50...

Страница 2: ...D VIEW AND PARTS LIST 18 CAUTION All individuals should take adequate precautions when changing the filter cartridges including protective gloves to avoid direct contact with the exhausted cartridges...

Страница 3: ...ls picked up in the environment by the water are measured as Total Dissolved Solids TDS In the Reverse Osmosis process dissolved minerals are separated from the incoming water Feed Water to produce th...

Страница 4: ...mbrane that has been rinsed for 24 hours The production rate of a new Membrane can decrease by 10 per year or more depending upon the scaling and fouling tendencies of the Feed Water TABLE B RECOMMEND...

Страница 5: ...5 MODEL CWQC50 TYPICAL UNDER SINK INSTALLATION DIAGRAM...

Страница 6: ...6 MODEL CWQC50 TYPICAL UNDER SINK INSTALLATION DIAGRAM...

Страница 7: ...7 MODEL CWQC50 TYPICAL UNDER SINK INSTALLATION DIAGRAM...

Страница 8: ...Extra plastic tubing Low range air pressure gauge Bicycle hand air pump or compressor Small bottle of liquid chlorine bleach Graduated measuring cylinder Paper towels whisk broom and assorted clean u...

Страница 9: ...a licensed plumber check with the local plumbing authority prior to installation In restricted under sink areas it may be easier to install the faucet first Allow adequate tubing lengths for any final...

Страница 10: ...not supplied into the Faucet Base opening This will separate and orient the Toggle Wings Position the Faucet Base so that the arrows are pointing in the direction that the faucet handle will face Tigh...

Страница 11: ...groove to prevent distortion of the tubing for larger tubing up to 5 8 OD use the large groove of the back plate Assemble and tighten the brass screw To pierce the tubing turn the Valve Handle fully c...

Страница 12: ...n of a mounting plate 1 The mounting bracket will accept either 10 or 12 5mm mounting screws spaced on 7 1 8 18 1 cm centers Allow at least 2 5 08 cm of clearance beneath the filter housings to accomm...

Страница 13: ...reconnect to the manifold plate 2 Start rinsing the system Slowly open the Feed Water Saddle Valve counterclockwise to its fully open position Open the faucet to allow air to escape while system is fi...

Страница 14: ...ensing Faucet This will allow the manifold to be de pressurized so you can safely remove the old modules 2 Loosen and remove the Sediment Carbon Pre and Carbon Post Filter Modules 2 Press upward and t...

Страница 15: ...lytubes to the new Post Filter Refer to Fig 5 Make sure the tubing is pressed all the way in to create a pressure tight connection NOTE If you want to pull the tubing out for some reason push the ring...

Страница 16: ...water from Holding Tank and with the faucet open adjust the air pressure to 5 7 psig 35 48 kPa range Holding Tank Valve is partially closed Open Valve The Dispensing Faucet is out of adjustment or fau...

Страница 17: ...ter overflows at the Dispensing Faucet Air Gap is blocked Clear Air Gap Rinse with vinegar for removal of calcium buildup Drain tubing is clogged Clear tubing Drain Clamp hole is misaligned Align with...

Страница 18: ...18 EXPLODED VIEW 1 2 3 5 6 7 8 9 10 11 14 14 15 12 13 4 OUT IN S7206W JG In line Activated Carbon Post Filter 16...

Страница 19: ...ner 1 12 S2116 6 Drain Restrictor 60 gpd 227 lpd 1 13 PK A6TEU4 MG Elbow Stem x 3 8 QC 1 14 S3551A 01 Sediment Carbon CS Module 2 15 S35715A 01 Membrane 50GPD Module 1 16 S7206W JG In line Activated C...

Страница 20: ...d freezing or hot water All replacement filters and membranes must be Charger Water Treatment Products filters and membranes or the warranty is void If the unit is altered by anyone other than Charger...

Отзывы: