Stand-on Floor Scale 

 

 

 

 

 

  Please keep the instruction manual at hand all the time for future reference.

 

Содержание MS3910

Страница 1: ...1 USER MANUAL MS3910 Stand on Floor Scale Please keep the instruction manual at hand all the time for future reference...

Страница 2: ...for 2019 Separate collection for waste of electrical and electronic equipment in accordance with Directive 2002 96 EC Indicates that device conforms to 93 42 EEC as amended by 2007 47 EC Medical Devi...

Страница 3: ...rnational copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co Ltd hereinafter Charder Charder is not liable for any damage caused by a failur...

Страница 4: ...II Indicator 22 A Indicator and Key Functions 22 B Display layout 23 IV Using Device 24 A Basic Operation 24 B Hold 24 C BMI 24 D Tare 25 E Pre Tare 26 F Print 29 V Device Setup 30 A Setting Time Date...

Страница 5: ...n stable flat solid non slippery surface Usage on soft surfaces ex carpet may result in inaccurate results Ensure all parts are properly locked and tightened before operating the device Safety Instruc...

Страница 6: ...gular maintenance and calibration Device does not require routine maintenance However regular checking of accuracy is recommended frequency to be determined by level of use and state of device If resu...

Страница 7: ...et hands Do not crimp the power cable and avoid sharp edges Do not overload extension cables connected to the device Route cables carefully to avoid tripping Keep device away from liquids Do not remov...

Страница 8: ...guidance RF emissions CISPR 11 Group 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electron...

Страница 9: ...hospital environment Surge IEC 61000 4 5 1kV line s to line s 2kV line s to earth 1kV line s to line s 2kV line s to earth Mains power quality should be that of a typical commercial or hospital enviro...

Страница 10: ...z 80 AM at 1 kHz 3 V m 80MHz to 2 7 GHz Portable and mobile RF communications equipment should be used no closer to any part of the device including cables than the recommended separation distance cal...

Страница 11: ...150 kHz to 80 MHz field strengths should be less than 3 V m Recommended separation distance between portable and mobile RF communications equipment and the MS3910 Stand on Floor Scale The device is i...

Страница 12: ...facturer NOTE1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE2 These guidelines may not apply in all situations Electromagnetic propagation is affected by ab...

Страница 13: ...13 II Installation A Assembly 1 Attach column to base 2 Secure column and base using screws...

Страница 14: ...14 B Inserting Batteries 1 Open battery housing cover 2 Accessing batteries 3 Use either rechargeable battery pack or AA batteries Take out the battery housing...

Страница 15: ...lled into the housing correctly 5 Install the battery housing into the compartment and make sure the right side of housing pin is facing towards inside of the connecting position Rechargeable Battery...

Страница 16: ...s of if the device has been used Battery can be charged by plugging device s exclusive adapter into AC Connector Port After a long period in storage e g 3 months the battery should run a full cycle ch...

Страница 17: ...17 C Using Adapter 1 Connect adapter to indicator before connecting to mains power supply 2 Disconnect adapter from mains power supply before unplugging adapter pin from indicator AC Connector Port...

Страница 18: ...to Column Item Name Quantity 1 M5x0 8x11 round head screw 4 2 Relief Bushing 2 3 Bracket for HM200D HM201D HM201M 2 Photo of display for reference only Please refer to the actual product 1 Assemble t...

Страница 19: ...ight Rod Compatible with HM200D HM201D HM201M 1 2 M5x10L flat head screw 2 3 Fixing block 2 4 M5x0 8x11 4 Photo of display for reference only Please refer to the actual product 2 Attach Height Rod to...

Страница 20: ...20 E Attaching Thermal Printer Item Parts Qty 1 M5 15L head screw 1 2 Screws for printer bracket 2 3 Printer bracket 1...

Страница 21: ...21 1 Install the side bracket 2 Install the thermal printer on the bracket...

Страница 22: ...p to 5 4 PRE TARE Pre tare the known weight of an object ex chair before beginning measurement 5 TARE Allows user to deduct weight from reading after measurement 6 PRINT When printer or PC is connecte...

Страница 23: ...23 B Display layout Definitions Stable symbol Indicate that weight is stable Zero symbol Weight is at zero Minor weight Weight under zero Low battery Battery needs to be charged or replaced...

Страница 24: ...ex an active child Note if fluctuation is too severe average weight determination will be difficult and hold may not function correctly 1 Switch on the device normally 2 Press the HOLD key HOLD will b...

Страница 25: ...late BMI based on change in height and weight NOTE Hold function can be used at this time if weight is unstable 5 Press BMI key to return to normal mode Category BMI kg m2 Risk of obesity related dise...

Страница 26: ...Weight or Input Manually After pre tare weights have been stored they can be recalled by holding the PRE TARE key for 3 seconds A Load Weight DESCRIPTION EXAMPLE Press M1 5 key after loading weight o...

Страница 27: ...hile digit is blinking Enter pre tare weight using 0 9 keys Ex to pre tare 5 0 kg of weight press 0 0 5 0 Ex to pre tare 13 5 kg of weight press 0 1 3 5 Press ENTER key to confirm the pre tare weight...

Страница 28: ...ake a beep sound C Recall Pre Tare Weight DESCRIPTION EXAMPLE Press and hold PRE TARE key for 3 seconds Indicator will display pre tare value M1 first The pre tare value will flash Press numeral keys...

Страница 29: ...tare weight must be under max capacity otherwise screen will show 0 00 after ENTER key is pressed and the operator will have to re input pre tare settings F Print If thermal printer is connected to in...

Страница 30: ...nth followed by day using numeral keys 0 9 Ex December 25th is 12 25 Input 1 2 2 5 Press HOLD key once completed to proceed to time setting Time Setting Enter time 24hr format using numeral keys 0 9 E...

Страница 31: ...ut off automatically after a certain period of time Auto off options 120 sec 180 sec 240 sec 300 sec off Press HOLD to toggle between time options and TARE to confirm selection Buzzer Beep When functi...

Страница 32: ...ff Press HOLD to toggle between on off and TARE to confirm selection Wi Fi optional If device has Wi Fi module installed Wi Fi function can be turned on or off Press HOLD to toggle between on off and...

Страница 33: ...ata Manager can be used to connect the device to a PC The software program can be downloaded from the Charder website LINK URL https www chardermedical com download htm 2 Connect USB cable to device i...

Страница 34: ...BMI calculation into software if needed Press Clear to clear all input NOTE information can also be input after weight measurement 2 Conduct measurement If Auto is selected results will be transmitte...

Страница 35: ...hanges and multiple measurements for the same subject we recommend not changing the default file name 2 Result example If previous results were saved in 20190201 csv new results also need to be saved...

Страница 36: ...ng a printer connected to the PC VII Wireless Connection If the device has the wireless or bluetooth module installed the indicator can transmit measurement results wirelessly Please see Charder wirel...

Страница 37: ...ng chemical electrochemical or electrical interference unless damage is attributable to negligence on the part of Charder If device is not covered under warranty a service maintenance charge will appl...

Страница 38: ...software is set up properly as indicated in this manual Distributor support required If the following errors occur we recommend contacting your local Charder distributor for repair or replacement ser...

Страница 39: ...aused by faulty loadcell or wiring Please contact distributor Counting Error too low Signal from loadcells too low Error normally caused by faulty loadcell or wiring Please contact distributor Zero co...

Страница 40: ...H mm Column 850 mm Device Weight 10 2 kg Key Functions On Off Zero Print BMI Hold Pre Tare Tare Clear Enter 0 9 M1 5 Power Supply Rechargeable battery pack optional or 6 AA batteries adapter Operatio...

Страница 41: ...41 B Standard Accessories No Accessories Item Spec Qty 1 USB cable WR 4001 1 2 12V Adapter 1 3 User manual CD IN 1258 1 4 Screw Castor wheel version M4 20 4...

Страница 42: ...42 C Power Adapter Standards Warning The device is only compatible with the power adapters specified in the dashed block below...

Страница 43: ...43 Notes _______________________________________________________ _______________________________________________________...

Страница 44: ...__________________________________________ _______________________________________________________ _______________________________________________________ _____________________________________________...

Страница 45: ..._____________________________________________ _______________________________________________________ _______________________________________________________ __________________________________________...

Страница 46: ...directives 93 42 EEC as amended by 2007 47 EC Medical Device Directive 2014 31 EU Non automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE ma...

Отзывы: