1
USER MANUAL
MS3400-1
Stand-on Floor Scale
Please keep the instruction manual at hand all the time for future reference.
Страница 1: ...1 USER MANUAL MS3400 1 Stand on Floor Scale Please keep the instruction manual at hand all the time for future reference...
Страница 2: ...part Device catalogue number model number Name and address of authorized representative in the European Union Device is a medical device Text indicates device category type Manufacturer s batch or lot...
Страница 3: ...national copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co Ltd hereinafter Charder Charder is not liable for any damage caused by a failure...
Страница 4: ...on 12 A Assembly 12 B Replacing Batteries 15 C Using Adapter 16 D Attaching Height Stadiometer to Column 17 E Using HM201M Height Stadiometer 18 III Indicator 20 IV Using Device 21 A Basic Operation 2...
Страница 5: ...ht related issues General Handling Device should be placed on stable flat solid non slippery surface Usage on soft surfaces ex carpet may result in inaccurate results Ensure all parts are properly loc...
Страница 6: ...not require routine user maintenance However regular checking of accuracy is recommended frequency to be determined by level of use and state of device or local metrology measuring instrument regulat...
Страница 7: ...edges Do not overload extension cables connected to the device Route cables carefully to avoid tripping Keep device away from liquids Do not remove the plug by yanking on the cable Use only a correctl...
Страница 8: ...ing domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Class A Volt...
Страница 9: ...an uninterruptible power supply or a battery Power frequency 50 60 Hz magnetic field IEC 61000 4 8 30 A m 30 A m The device power frequency magnetic fields should be at levels characteristic of a typ...
Страница 10: ...y not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations fo...
Страница 11: ...eparation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3...
Страница 12: ...12 II Installation A Assembly 1 Insert column into column seat 2 Insert and fasten 3 x M4 0 7 15 screws at the bottom of the base...
Страница 13: ...13 3 Route the cable along the gap in the column seat 4 Place bottom cover in position Insert and fasten 4 x M4 0 7 8 screws...
Страница 14: ...14 Using wheel castor optional 1 If installed on device wheel castor is located behind column 2 Press the brake down to lock the castor wheel...
Страница 15: ...er and remove battery holder from compartment 2 Disconnect rechargeable battery cable from connector in the battery compartment Connector in the battery housing 3 Connect cable with connector and inse...
Страница 16: ...battery should run a full cycle charge discharge to allow it to restore full capacity If prompt displays on the LCD please charge battery promptly to avoid battery damage C Using Adapter 1 Connect ada...
Страница 17: ...ks to column using four flat head screws Step 2 Attach height rod to blocks using two flat head screws Item Name Quantity 1 Fixing block screws 4 2 Fixing blocks 2 3 Height Rod to fixing block screws...
Страница 18: ...18 E Using HM201M Height Stadiometer Measurement over 121 cm 1 Pull out rod 2 Unfold head piece to horizontal position A 3 Height reading found at point A...
Страница 19: ...19 Measurement under 121 cm 1 Fold head piece and press buckle 2 While pressing on buckle pull down head piece B 3 Height reading found at point B...
Страница 20: ...ing value used when weight is unstable Press and hold for 3 seconds to enter BMI mode 2 UNIT WEIGHT Switch between kg lb Change height value when indicator is in BMI mode 3 ON ZERO OFF Power on or pow...
Страница 21: ...ize ex an active child Note if fluctuation is too severe average weight determination will be difficult and hold may not function correctly 1 Switch on the device normally 2 Press the HOLD BMI key An...
Страница 22: ...ow Normal 18 5 24 9 Average Over 24 9 29 9 Slightly Increased Obese I 30 0 34 9 Increased Obese II 35 0 39 9 High Obese III 40 Very High World Health Organization adult BMI standards D Tare The tare f...
Страница 23: ...ckwise to extend and try again External objects interfering with measurement platform Clear platform of objects and try again Device may not function properly on soft surfaces such as carpets or lawns...
Страница 24: ...vice Replace batteries or plug in adapter Overload Total load exceeds device s maximum capacity Reduce weight on measurement platform and try again Counting Error too low Signal from loadcells too low...
Страница 25: ...Weight Tare Data Transmission RS232 NOTE Device should be connected to network by qualified distributors only Power Supply Rechargeable battery Power adapter Operation Temperature Humidity 5 35 15 85...
Страница 26: ...________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________...
Страница 27: ...________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________...
Страница 28: ...andards outlined in the following directives 2014 31 EU Non automatic Weighing Instruments Directive RoHS Directive 2011 65 EU and Delegated Directive EU 2015 863 Authorized EU Representative Manufact...