1
USER MANUAL
MHS2710
Lift Scale
Please keep the instruction manual at hand all the time for future reference.
Страница 1: ...1 USER MANUAL MHS2710 Lift Scale Please keep the instruction manual at hand all the time for future reference...
Страница 2: ...for 2019 Separate collection for waste of electrical and electronic equipment in accordance with Directive 2002 96 EC Indicates that device conforms to 93 42 EEC as amended by 2007 47 EC Medical Devi...
Страница 3: ...rnational copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co Ltd hereinafter Charder Charder is not liable for any damage caused by a failur...
Страница 4: ...l Warnings 12 B Inserting Batteries 15 III Indicator and Key Functions 16 IV Using Device 18 A Basic Operation 18 B Hold 18 C BMI 19 D Tare 19 V Device Setup 20 VI Wireless Connection 21 VII Troublesh...
Страница 5: ...before operating the device Safety Instructions Before putting device into use please read this user manual carefully It contains important instructions for installation usage and maintenance of devic...
Страница 6: ...device as it may cause damage to the internal electronics Maintenance Please contact your local Charder distributor for regular maintenance and calibration Device does not require routine maintenance...
Страница 7: ...to a designated collection points for electronics Further information should be provided by local waste disposal authorities Warning Keep device away from liquids Do not under any circumstances disman...
Страница 8: ...ance RF emissions CISPR 11 Group 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic eq...
Страница 9: ...tal environment Surge IEC 61000 4 5 1kV line s to line s 2kV line s to earth 1kV line s to line s 2kV line s to earth Mains power quality should be that of a typical commercial or hospital environment...
Страница 10: ...AM at 1 kHz 3 V m 80MHz to 2 7 GHz Portable and mobile RF communications equipment should be used no closer to any part of the device including cables than the recommended separation distance calculat...
Страница 11: ...ange 150 kHz to 80 MHz field strengths should be less than 3 V m Recommended separation distance between portable and mobile RF communications equipment and the MHS2710 Lift Scale The device is intend...
Страница 12: ...n and reflection from structures objects and people II Installation A General Warnings To ensure safety correct assembling procedure must be followed Tools required hexagon screwdriver torque wrench 1...
Страница 13: ...13 Set Screws Set screws are used to fix direction of lift scale and should not be loosened Ensure screws are tight before use Set screw...
Страница 14: ...inaccurate reading Horizontal rotation Although not strictly necessary device should ideally be installed on lift system utilizing 360 degree swivel bearing After assembly at lifter rotation should id...
Страница 15: ...es a rechargeable battery pack When power is low please recharge the battery pack using the micro USB port When the port light is blinking red battery is being charged When the port light is stable gr...
Страница 16: ...e Negative weight Zero Low battery Key Function 1 Power on or power off Reset display to 0 0 kg display can be used if within 2 of full capacity Press and hold for 3 seconds to turn off 2 Determine st...
Страница 17: ...een kg and lb Last used unit will be stored in memory non functional on OIML model Indicator 1 HOLD indicates if hold is active 2 NET indicates if current result is net weight 3 GROSS indicates if cur...
Страница 18: ...Hold The hold function determines average weight designed to be used if subject s weight will not stabilize ex an active child Note if fluctuation is too severe average weight determination will be d...
Страница 19: ...24 9 29 9 Slightly Increased Obese I 30 0 34 9 Increased Obese II 35 0 39 9 High Obese III 40 Very High World Health Organization adult BMI standards NOTE though BMI is calculated in the same way sub...
Страница 20: ...revious menu option to confirm selection enter submenu Auto Power Off Instruct device to shut off automatically after a certain period of time Auto off options 60 sec 120 sec 180 sec 240 sec 300 sec o...
Страница 21: ...all be accepted for damage caused through any of the following reasons unsuitable or improper storage or use incorrect installation or commissioning by the owner or third parties natural wear and tear...
Страница 22: ...ave or read data Indicator shows ERRL after device is switched on Keys not responding Buzzer malfunction Error Messages Error Message Reason Action Low battery warning Voltage of battery is too low to...
Страница 23: ...LCD Screen 1 0 inch LCD screen 5 1 2 digits Dimensions Overall 122 W x 52 D x 180 H mm Device Weight 1 04 kg Key Functions On Off Zero Tare Hold BMI Unit non OIML models Power Supply Rechargeable batt...
Страница 24: ...24 B Technical Data for Joints SS 6381 16mm SS 6384 13mm SS 6385 12mm SS 6662 14mm SS 6663 24mm SS 6664 30mm SS1 0681 24mm SS1 0691 29mm SS 7121 18 5mm SS 7122 6mm SS 00058 7 7mm SS1 0641 12mm...
Страница 25: ...________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________...
Страница 26: ...________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________...
Страница 27: ...________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________...
Страница 28: ...directives 93 42 EEC as amended by 2007 47 EC Medical Device Directive 2014 31 EU Non automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE ma...