Channel Safety Systems EntriTech Series Скачать руководство пользователя страница 1

 
Issue 1 June 2012 

 
 
 
 
 

Operation and Installation Manual 

 

For EntriTech series hands free indoor audio handsets 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Wiring 

1.  The audio handset is supplied with pre-wired looms & sockets, these are 

connected to the equipment in their correct location. The plugs and sockets are 
‘keyed’ to stop incorrect installation. Please do not force the sockets in to the 
plugs. The pre wired looms should be extended via a suitable junction box. 
 

 

 

Extension cable should be of minimum diameter 

0.5mm

2

, the maximum distance 

from an outdoor station to the farthest monitor distance should be 

70m. 

 

2. Each 

Monitor/handset 

should be connected parallel

.   

Maximum number of video monitors is 4; the maximum number of audio 
handsets is 2. 

 

The Power supply unit requires a 230vAC 50Hz supply which should be protected by 
a suitable fuse or MCB.  

Lock release 

Answer/call 

Отзывы: