32
3.3.1
when choice VGA mode by remote device PW113 controls MST9885 by I
2
C
bus enable SiI161B and VPC3230 let them work in low consume mode which can save power
and reduce interfere At the moment VGASEL signal from PW113 output parks VGA input
channel in PI5V330. If VGA signal inputs, MST9885 outputs Horizontal and Vertical Sync
signal and data signal and send to PW113 which outputs format commutation data . After
DS90CF383(DS transmitter) it transforms to the signal fitting the PDP panel demand because
SiI161B DS90CF383 both in normal work state when DVI signal inputs, display video if no
VGA signal MST9885 can not output digital Horizontal and Vertical Sync signal after examined
by PW113,displays pc icon on the left and top of PDP panel other part display black. If no
input after 60 sec, it hints to enter
“
save power mode
”
At the moment , MST9885 in normal
work state examines VGA signal ceaselessly so it can arouse automatically in VGA mode. It is
said that when VGA signal inputs, it can work normally from standby state
3.3.2
when in TV AV YCbCr mode by remote device PW113 controls VPC3230 by
I
2
Cbus otherwise PW113 controls MST9885 on the fly output in high impedance state by
I
2
Cbus.Because tuner N901 VPC3230 DS90CF383 all in normal work state when video signal
inputs PDP panel display normally if no video signal input under the control of PW113 PDP
panel displays blue background if no signal 15 mins power off automatically and into standby
state. It can not arouse automatically
3.3.3
When in DVI(digital RGB) mode by remote device PW113 controls SiI161B and
enables VPC3230 and let it working in low consume mode otherwise PW113 controls MST9885
on the fly output in high impedance state by I
2
C bus because SiI161B DS90CF383 both in
normal work state when DVI signal inputs, display video if no DVI signal SiI161B do not
output digital Horizontal and Vertical Sync signal after examined by PW113,displays DVI icon
on the left and top of PDP panel
other part display black. If no input after 60 sec, it hints to
enter
“
save power mode
”
work state At the moment ,SiI161B in normal work state examines
DVI signal ceaselessly so it can arouse automatically in DVI mode. It is said that when DVI
signal inputs, it can work normally from standby state
3.4
power supply system
3.4.1
main power supply
D6V steady voltage to 5V supply for VPV3230 AD9883 analog power 5V-ST standby
power to PW113 AM29LV800BT ROM
24LC32 MAX202E VDD(3.3V) VPC3230
MST9885 DS90CF383 power +32V RF tuner tuning power A6V steady voltage to Av board
5V etc. A12V steady voltage to AV board 8V etc. 12VAMP sound amplifier TA2024 power
3.4.2 main power form and power branch
3.4.2.1 5V-STpower branch