Volume crated:
175 cu. ft.
Shipping weight crated:
1,000 lbs.
Dimensions shown in inches
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
utilities
1
Electrical
A
Machine connection (see Table A)
B
Booster connection (see Table B)
2
Hot Water
3/4” NPT 180°F/82°C min. hot water
connection. (Machine without booster.)
3/4” NPT 140°F/60°C min. hot water
connection. (40°F/22°C rise booster)
3/4” NPT 110°F/49°C min. hot water
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
3
Drain
1-1/2” NPT machine connection.
Maximum flow 15 gpm.
4
Steam
A
3/4” NPT machine connection.
Flow pressure 15-30 PSI. (Steam coil)
B
3/4” NPT machine connection.
Flow pressure 15-30 PSI.
(Steam injector)
5
Condensate
(no back pressure)
1/2” NPT machine return to boiler
6
Vents
A
Load end: 200 CFM @ 1/4” S.P.
B
Unload end: 400 CFM @ 1/4” S.P.
(With blower-dryer increase room
ventilation by 600 CFM.)
84” Two Tank with Heavy Duty 36” Prewash
Rack Conveyor High Temperature
Dishwashing Machine
Model 120 HdPW
SPeCIFICATIoNS
Capacity
Racks per hr. (NSF rated)
356
Wash tank (US gal.)
21
Conveyor speed (ft/min.)
9.9
Motor Horsepower
Drive
1/6
Prewash
1
Wash 3
Rinse 3
Water Consumption
US Gal. per hr. (max. use)
131
US Gal. per rack
.37
Heating
Tank Heat, electric (kW)
25
Tank heat, steam
(lbs/hr. required at
15 PSI flow pressure)
75
Electric booster (built-in)
(kW supplied for 40°F rise)
15
Electric booster
(kW supplied for 70°F rise)
24
Steam booster (lbs./hr.
required for 40°F rise)
75
Steam booster (lbs./hr.
required for 70°F rise)
120
Venting
Load end (minimum CFM)
200
Unload end (minimum CFM) 400
Standard 20” x 20”
rack complement
Peg
2
Flat
1
Warning:
Plumbing and electrical connections
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary,
safety codes and the National Electrical Code.
Note:
Water Hammer Arrestor (meeting ASSE-
1010 standard or equivalent) to be supplied (by
others) in common water supply line at service
connection.
Plumbing Notes:
Because of the variation
in house-supplied steam and water pressures,
steam and water pressure regulating valves
(PRVs) may be needed. (Water PRV is standard on
machines with booster.) The PRVs can either be
purchased from Champion or obtained locally.
Venting Notes:
Fabricated duct size:
3-7/8” x 15-7/8” (Outside dimensions)
TABle B - BooSTeR CoNNeCTIoN
40°F/22°C Rise – 15kW
Electric built-in booster (booster only)
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
42
50
50
240/60/3
36
45
45
480/60/3
18
25
25
575/60/3
15
20
20
70°F/39°C Rise – 24kW
Electric built-in booster (booster only)
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
67
80
80
240/60/3
58
70
70
480/60/3
29
35
35
575/60/3
24
30
30
Machine only
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
171
225
225
240/60/1
150
200
200
208/60/3
95
125
125
240/60/3
83
100
100
480/60/3
41
50
50
575/60/3
32
40
40
TABle A - MACHINe CoNNeCTIoN
Machine and steam built-in booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
41
50
50
240/60/1
36
50
50
208/60/3
20
25
25
240/60/3
17
25
25
480/60/3
9
15
15