100520 - 8750W PORTABLE INVERTER GENERATOR
OPERATION
19
WARNING
During operation the muffler and exhaust fumes will become
hot. If adequate cooling and breathing space are not supplied,
or if the generator is blocked or enclosed, temperatures can
become extremely heated and may lead to fire.
Surge Protection
Electronic devices, including computers and many programmable
appliances use components that are designed to operate within a
narrow voltage range and may be affected by momentary voltage
fluctuations. While there is no way to prevent voltage fluctuations,
you can take steps to protect sensitive electronic equipment.
–
Install UL1449, CSA-listed, plug-in surge suppressors on the
outlets feeding your sensitive equipment.
Surge suppressors come in single- or multi-outlet styles.
They’re designed to protect against virtually all short-duration
voltage fluctuations.
Starting the Engine
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never
start or stop the generator manually with electrical devices
plugged in or turned on.
3. Turn the gasoline fuel valve to the “ON” position.
4. Pull the choke to the “CHOKE” position.
Electric Start
1. Press and hold the ignition switch to the “START” position.
Release as the engine begins to start. If the engine fails to
start within five seconds, release the switch and wait at least
ten seconds before attempting to start the engine again.
2. Once engine starts, push choke button to the “RUN” position.
CAUTION
If the ignition switch is held down in the “START” position
longer than 5 seconds it could damage the starter.
Manual Start
1. Push the engine switch to the “ON” position.