CHAMPION PUMP 

P PERFORMANCE CURVE

30

PUM

   

Installation and Operation Manual 

  

     

Models:  CPS5HT, CPS5HTA 

 

        

Submersible Sump/Effluent

 

 
    

 

Thank you for purchasing this 

CHAMPION PUMP! 

The CPSHT series 

pumps are heavy duty cast iron sump/effluent pumps.  We back these 

Champion 

products with 

Champion 

service and a 

Champion 

attitude.  Please read, save, and 

follow these instructions to ensure 

Champion 

performance. 

   

     

    

 

                                      

Product Warranty 

Date of Manufacture and Warranty Tag is on pump cord. 

 

LIMITED WARRANTY:  

 We warrant to our immediate customer and to the ultimate 

consumer that products of our manufacture will be free of defects in material and 
workmanship under normal use and service for one year (12 months) from the 
date of installation, or 18 months from the date of manufacture, which ever comes 
first.  We will repair or replace, at our option, to the original purchaser any part or 
parts of our product found upon our examination to be defective.  Please call 
Champion Pump Company, Inc. (419-281-4500) for instructions.  Be prepared to 
provide the model number, the date code and/or serial number and proof of the 
date installed when exercising this warranty.  Warranty tag (Required) is on the 
pump power cord.  All transportation charges on products or parts submitted for 
repair or replacement must be paid by purchaser.  This limited warranty does not 
cover products which have been damaged as a result of accident, abuse, misuse, 
neglect, improper installation, improper maintenance, or failure to operate in 
accordance with Champion Pump Company, Inc. written instructions.  

UNDER NO 

CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR ANY OTHER DIRECT OR 
CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOST PROFITS, 
LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION 
WHICH DAMAGES ARE CAUSED BY ANY DEFECTS IN MATERIAL AND/OR 
WORKMANSHIP AND/OR DAMAGE OR DELAYS IN SHIPMENT.  THIS WARRANTY 
IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTY, 
INCLUDING ANY WARRANTY OF MERCHANTABILTIY OR FITNESS FOR A 

PARTICULAR PURPOSE.  

Some states do not allow limitations on how long an 

implied warranty lasts, or do not allow the exclusions or limitations of incidental or 
consequential damages, so the above limitations might not apply to you.   This 
limited warranty gives you legal rights, and you may also have other legal rights 
which vary from state to state. 

 

12-0011-0001 

 

 

 

               www.championpump.com

4                                             12/13 

 

BEFORE OPERATION – Important Product and 
Safety Information – 

WARNINGS – 

Personal Injury 

and/or property damage could result if not adhered to. 

!

 

Risk of Electric Shock – Fatal electric shock could occur.  Always 
disconnect the power source before attempting to install, service, 
relocate or check the pump.  Never touch pump, pump motor, water, or 
discharge piping when pump is connected to electrical power.  Never 
enter a wet or flooded area, basement, basin, etc. that is in contact with 
the pump or electrical circuit before power supply has been 
disconnected. 

!

 

Pump has not been investigated for use in swimming pool areas or any 
area that might reasonably expect aquatic, animal, or human entrance.  
Precautions should be taken to prevent such entrance during use. 

!

 

Connect only to a properly grounded, grounding type receptacle.  Use of 
a ground fault circuit interrupter (GFCI) is required for maximum safety. 

!

 

All wiring must be performed by qualified electrician in accordance with 
all local and national electric code. 

!

 

When power source or supply is turned off (in open position) a lock and 
tag out should be used to prevent accidental power application or 
activation. 

!

 

Do not use extension cord or cut off grounding pin.  Should be installed 
on separate 15 AMP circuit breaker. 

!

 

Use only with a properly sized (input AMPS, volts, HP, temperature)  
motor controller. 

!

 

Do not use to pump flammable/explosive liquids such as gasoline, fuel 
oil, kerosene, and /or chemicals, salt water, etc. 

!

 

Do not use pump in an explosive atmosphere or classified as hazardous 
per NEC, ANSI/NFPA 70, or temperatures above rating. 

!

 

Make sure pump is on hard level bottom in sump, do not set directly on 
earth, gravel, or other debris.  This could cause excessive wear or 
possible jamming and flooding. 

!

 

Make sure pump is secure in basin and piping is firmly supported so that 
pump cannot move, not allowing liquid level switch to interfere with 
basin all or other obstacle preventing proper operation.  Flooding or 
overheating could occur if not prevented. 

 