background image

CARE OF YOUR OPENER

When properly installed, opener will provide high performance with
a minimum of maintenance. The opener does not require additional
lubrication.

Limit and Force Settings:

These settings must be checked and prop-

erly set when opener is installed. Weather conditions may cause some
minor changes in the door operation, requiring some re-adjustments,
particularly during the first year of operation

.

Refer to 

Setting the Limits and Force

on page 10. Follow the instruc-

tions carefully and 

repeat the safety reverse test after any adjust-

ment.
Remote Control:

The remote control may be secured to a car sun visor

with the clip provided. Additional remotes can be purchased at any time
for use in all vehicles using garage. Refer to Accessories. Any new
remotes must be programmed into the opener.

Remote Control Battery:

The lithium batteries should produce power

for up to 5 years. If transmission range lessens, replace battery .

To Change Battery: 

To replace batteries, use the visor clip or screw-

driver blade to pry open the case. Insert batteries 

positive side up

. To

replace cover, snap shut along both sides. Do not dispose of the old
battery with household waste. Take batteries to a proper disposal cen-
ter.

Your opener can be activated by any of the following devices:
• 

The Lighted Door Control Button. 

Hold the button down until door

starts to move.

• 

The Outside Keylock or Keyless Entry System 

(if you have

installed either of these accessories). 

• 

The Remote Control Transmitter.

Hold the push button down until

the door starts to move.

Opening the Door Manually: Door should be fully closed if possi-
ble. Weak or broken springs could allow an open door to fall rap-
idly. Property damage or serious personal injury could result.

The door can be opened manually by pulling the release handle down.
To reconnect the door, pull the release handle down and toward the
opener.

Do not use the manual release handle to pull the door opener
or closed. When the Opener is Activated by Remote Control or
Lighted Door Control Button:

1. If open, the door will close. If closed, the door will open.
2. If closing, the door will stop. 
3. If opening, the door will stop (allowing space for entry and exit of

pets and for fresh air).

4. If the door has been stopped in a partially open or closed position, it

will reverse direction. 

5. If an obstruction is encountered while closing, the door will reverse.
6. If an obstruction is encountered while opening, the door will reverse

and stop. 

7. The optional Protector System™ uses an invisible beam which, when

broken by an obstruction, causes a closing door to open and pre-
vents an open door from closing. It is STRONGLY RECOMMENDED
for homeowners with young children.

Allow a 15 minute cooling period after 5 continuous operations
of the opener. 

The opener light 

will turn on: 1. when opener is initially

plugged in; 2. when the power is briefly interrupted; 3. when the opener
is activated. 
The light turns off automatically after 2-1/2 minutes. Bulb size is
230V/40W maximum.

OPERATION OF YOUR OPENER

MAINTENANCE OF YOUR OPENER

Once a Month: 

Repeat safety reverse test.

Make any necessary adjustments.

• 

Manually operate door.

If it is unbalanced or binding, call for profes-

sional garage door service.

• 

Check to be sure door opens and closes fully

. Set Limits and/or Force

if necessary.

Once a Year:

• 

Oil door rollers, bearings and hinges.

The opener does not require

additional lubrication. Do not grease the door tracks.

• GREASE THE RAIL AND THE TROLLEY.

Input Voltage ...........

230-240 VAC, 50Hz

Max. Pull Force .......

600N (LM600A), 800N (LM800A), 1000N
(LM1000A)

Power ......................

6Nm (LM600A), 8Nm (LM800A), 10Nm 
(LM1000A)

Watts .......................

130W (LM600A), 165W (LM800A), 190W
(LM1000A)

Standby Power ........

5,5W (LM600A), 6.0W (LM800A), 6.5W
(LM1000A)

Motor

Type ........................

DC gearmotor permanent lubrication

Noise level ..............

57dB

Drive Mechanism

Drive........................

Chain/belt with two-piece trolley on steel
rail.

Length of Travel ......

Adjustable to 2,3m (7-1/2 feet)

Travel Rate..............

5"-7" (127-178mm) per second

Lamp .......................

On when door starts, off 2-1/2 minutes 
after stop.

Door Linkage...........

Adjustable door arm. Pull cord trolley
release.

Safety

Personal ..................

Push button and automatic stop in 

down

direction. Push button and automatic
stop in 

up

direction.

Electronic ................

Automatic force adjustment 

Electrical..................

Transformer overload protector and low
voltage push button wiring.

Limit Device ............

Optical RPM/Passpoint detector.

Limit Adjustment......

Electronic, Semi and Fully Automatic.

Start Circuit..............

Low voltage push button circuit.

Dimensions

Length (Overall) ......

3,2m (122-1/2")

Headroom Required

30mm

Hanging Weight.......

14,5 kg (32 lb)

Receiver

Memory Registers ...

16 (LM600A), 32 (LM800A) & 64 
(LM1000A)

Operating Frequency 

433.92MHz

SPECIAL NOTE:

Chamberlain strongly recommends that the protector

system be installed on all garage door openers

.

SPECIFICATIONS

6-en

Содержание LM1000A

Страница 1: ...LM1000A Instruktie LM800A LM1000A Instrucciones LM800A LM1000A Manuais LM800A LM1000A Istruzioni LM800A LM1000A LM800A LM1000A Instruktioner LM800A LM1000A Instruksjonene LM800A LM1000A Instruktioner...

Страница 2: ...Excessive force will interfere with the proper operation of the Safety Reverse System or damage the garage door Permanently fasten the caution label adjacent to the wall mounted door control control b...

Страница 3: ...il 5 Insert carriage bolt 6 through header sleeve bracket 7 Loosely thread spring nut 8 and flat washer 9 onto carriage bolt Insert carriage bolt 6 of header sleeve assembly 7 into bold cut out in pul...

Страница 4: ...nging brackets with screw lock washer and nut 3 Check to make sure rail is centered over the door REMOVE 25mm 1 board Operate door manually If door hits the rail raise header bracket Use rail grease a...

Страница 5: ...this or other rolling code garage door openers OPEN CLOSE STOP OPERATION only if you have a Multifunction door control Your remote control can be programmed to operate one door using all 3 buttons th...

Страница 6: ...or must reverse on the obstruction If the door stops on the obstruc tion remove obstruction and repeat Setting the Limits step 26 Repeat test When the door reverses on the 40mm obstacle remove the obs...

Страница 7: ...artially open or closed position it will reverse direction 5 If an obstruction is encountered while closing the door will reverse 6 If an obstruction is encountered while opening the door will reverse...

Страница 8: ...ngaged all door locks Review installation instruction warnings on page 1 Is there a build up of ice or snow under door The door may be frozen to ground Remove any obstruction The garage door spring ma...

Страница 9: ...owner for the repair and or replacement parts and or product Defective parts will be repaired or replaced with new or factory rebuilt parts at Chamberlain s option If during the warranty period the p...

Страница 10: ...12 1 2 3 12 4 6 9 8 9 11 13 14 7 15 10 7 9 1 2x 5 2 2x 2 2x 4 2x 6 2x 5 2x 15 1x NOTICE 5 1x 1x 10 2x 13 2x 3 4x 7 4x 8 4x 9 4x 14 3x 10x 11 2x 12 2x 16 1x 17 2x 4 8 7 6 9 10 1 6 7 10 Chamberlain GmbH...

Страница 11: ...12V DC Pb Cd Hg 12B380 41A5639 7 10A20 41A5800 210C42 183D177 183D178 7423CR3 12C855 171A28 31D525 41A5801 1 1 7m 41A5801 2 3m 41A5801 2 2 5m 41A5801 3 3 0m 31D537 41A5844 2 3m 41A5844 1 2 5m 41A5844...

Отзывы: