Chamberlain LiftMaster CB202EV Скачать руководство пользователя страница 1

®

RADIO MODULERADI

O

 M

O

DUL

E

CB202EV

Instruction  

  

Содержание LiftMaster CB202EV

Страница 1: ... RADIO MODULE RADIO MODULE CB202EV Instruction ...

Страница 2: ...F PUSH BUTTONS P1 P2 P3 RESET 5 RADIO TRANSMITTERS 6 FLASHING LAMP 6 KEYSWITCH 6 STOP SWITCH 6 SAFETY EDGE 6 CONTACT EDGE 6 SAFETY ACCESSORY KIT myQ DOOR MONITOR 6 PHOTOCELLS 7 RADIO AND RADIO PROGRAMMING 7 PROGRAM INTERNET GATEWAY DOOR MONITOR 8 LOOP DETECTOR 9 DIP SWITCH SETTINGS 9 INITIAL OPERATION BASIC SETTING 10 12 TIMER TO CLOSE AUTO CLOSE 12 FORCE TORQUE OF MOTOR 12 DISPOSAL 12 BATTERY DIS...

Страница 3: ...with your gate manufacturer for an opener installation reinforcement kit Activate opener only when the gate is in full view free of obstructions Do not allow children to play near the gate Humidity and water destroy the control board Make sure under all circumstances that water humidity or dammed up water cannot penetrate the control board covering Frequently examine the installation for imba lanc...

Страница 4: ...st be mounted at a height of up to 2 5m INSTALLATION OF CONTROL BOARD The CB202EV control board was designed for installation in a special covering under the housing of the sliding gate drive The installation of the control board is allowed only after the completion of the mechanical installation All work on the control board must be performed after disconnecting it from the mains Turn on the powe...

Страница 5: ...nd armoured or suitably protected You may also consult your local electrician Terminals The terminal blocks on the controller can be removed pull to facilitate a convenient wiring and are pushed back only while installing the controller Even if a terminal strip is not in use it must be pushed back The wiring is done as described in the wiring diagram Plugs available on the motor and the transforme...

Страница 6: ...d functions required for safe operation The electronics provides an ideal and matching closing force When installed and adjusted correctly the gate can be stopped manually During operation the gate can be stopped via remote control push button or key switch The gate requires a firm stop for OPEN and CLOSED position Humidity and water destroy the control board Make sure under all circumstances that...

Страница 7: ...ic also refer to page 13 LEARN yellow Programming indicator ON flashing programming is active OFF off CH1 red Remote control programming for complete opening ON New remote can be programmed OFF off CH2 red Remote control programming for partial opening Refer to CH1 DESCRIPTION OF PUSH BUTTONS P1 P2 P3 RESET P1 P2 P3 P1 P1 P1 P2 P2 P3 P3 DIP RADIO PROGRAM P1 DIP RADIO PROGRAM P2 RESET Limit setting...

Страница 8: ...rking according to the 8 2 kilo ohm principle can be connected to the control board Terminals Stop 8 2 kOhm i e a 8 2 kilo ohm test resistor is attached to the end of the safety edge It ensures that the electric circuit is monitored permanently The control board is supplied with an 8 2 kilo ohm resistor installed Several safety PHOTOCELLS OPTIONAL MODELS 771E 772E The use of photocells is recommen...

Страница 9: ...te to open Connection between 2 COM adjustable DIP PHO 2 MODE is off active when gate is closing DIP PHO 2 MODE is on active when gate is opening RADIO AND RADIO PROGRAMMING PROGRAM DELETE REMOTE CONTROLS The receiver has two channels CH1 and CH2 The respective LEDs CH1 and CH2 are assigned to these two channels Receiving a signal from a programmed remote control button CH1 fully opens the gate Re...

Страница 10: ...hing the LEDs will blink 3 times and go out 7 The App will tell you if programming was successful and will prompt you to assign a name to the gate PROGRAM DOOR MONITOR Using the RESET Button on the control board 1 Connect power to the door monitor Position the door monitor in a convenient visible place inside the house If this place is too far from the gate opener the connection may not be possibl...

Страница 11: ...topped When used for a safety edge the gate reverses for aproximately 20 cm OFF Factory setting is 8 2KOhm Safety edge or 8 2kOhm resistor is required ON Emergency stop required In this case the resistor must be removed and replaced by the switch or a switch circuit OPEN PED Defines if a key switch opens the gate completely or partially Note If the DIP OPEN PED is on and timer to close is activate...

Страница 12: ...E and engage gate opener 2 Press buttons P1 P2 and P3 at the same time for about 2 3 sec LED LEARN starts to flash 3 Now watch the gate The gate can be moved in both directions using the button P1 Press the button P1 several times 1 2 seconds each time to understand the function of the button If none of the buttons are pressed for about 15 seconds the control switches back to normal operation Repe...

Страница 13: ...rnative PROGRAMMING THE DISTANCE ADVANCED INDIVIDUAL Note The button P1 must be pressed several times in this program With each press of the button the position at which the soft stop slow speed starts is saved Long or short soft stop settings are possible 1 Gate is closed gate position is Close Limit LED CLOSE LIM glows 2 Press P1 and P2 simultaneously for a longer time about 5 6 seconds until th...

Страница 14: ...ly while programming the travel distance Thrust can only be modified by programming the travel distance again If gate movement is impeded by weather or changes to the installation rust or inappropriate lubrication it may have to be repaired The control board complies with the latest EU guidelines One of these guidelines specifies that the closing forces at the gate edge must not exceed 400N 40 kg ...

Страница 15: ...damaged wire in powercable C Back up battery optional accessory empty EEPROM Fault Power up failed Defect on relay or major electrical component A Overload B Bad wiring wrong C water in photocells bad installation D a photocell was connected before but not removed disconnected Remedy Check terminals precisely Consider wire lengths Progamming travel distance failed because the gate never reached th...

Страница 16: ...g Check gate area for objects check photocells reprogram travel distance Function and connection must be checked Only works if the 2 cable photocell 771E ML or 772E ML installed At least 1 pair of photocells active in OPEN or CLOSED must be connected 1 Programming remote control 2 Find and rectify fault s see description of diagnostic LEDs 3 Check photocell connection programming 4 Check terminals...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ... EG und der EG Niederspannungs Richtlinie 2006 95 EG Insbesondere wurden folgende harmonisierte Normen angewandt DIN EN 12453 Nutzungssicherheit kraftbetätigter Tore Anforderungen DIN EN 12604 Tore mechanische Aspekte Anforderungen EN 61000 6 3 Elektromagnetische Verträglichkeit EMV Teil 6 3 Fachgrundnormen Störaussendung Wohnbereich Geschäfts und Gewerbebereiche sowie Kleinbetriebe EN 60335 1 Sic...

Отзывы: