For use with LiftMaster 1300 & 3000 Series 
Garage Door Openers.

Installation

Locate control console within sight of door, at a
minimum height of 5' (1.5 m) where small
children cannot reach, away from moving parts of door and
door hardware. If installing into drywall, drill 5/32" holes and
use the anchors provided. For pre-wired installations (as in
new home construction), it may be mounted to a single gang
box (Figure 1).

NOTE:

The functional temperature range of the control

console is between -4° F (-20° C) and 122° F (50° C). Scroll
speed of display is slower at lower temperatures although
the control console remains fully functional.

CAUTION:

Continuous exposure of the control console to

temperatures below -22° F (-30° C) may damage the LCD
screen.

SPECIAL NOTE:

Only one 398LM can be connected to

each garage door opener. If additional wall controls are
desired to operate the same garage door opener, it is
recommended to use model 378LM wireless wall control
as the secondary control console. 

1. Disconnect power to opener.

2. Strip 7/16" (11 mm) of insulation from one end of bell wire

and connect to the two screw terminals on back of control
console by color: white wire to the W (2) and white/red
wire to the R (1) (Figure 2).

3. Remove push bar cover by gently prying at the

lower/middle portion of the cover with a small flat-head
screwdriver. Fasten with 6AB x 1-1/4" self-tapping screws
(drywall installation) or 6-32 x 1" machine screws
(into gang box) as follows:

• Install bottom screw, allowing 1/8" (3 mm) to protrude

above wall surface.

• Position bottom of control console on screw head and

slide down to secure. Adjust screw for snug fit.

• Drill and install top screw with care to avoid cracking

plastic housing. 

Do NOT overtighten.

• Replace cover by inserting top tabs first and then snap

cover in place.

4.

(For standard installations ONLY)

Run bell wire up wall

and across ceiling to motor unit. Use insulated staples to
secure wire in several places. Do NOT pierce wire with a
staple, creating a short or open circuit.

5. Strip 7/16" (11 mm) of insulation from end of bell wire.

Connect bell wire to the quick-connect terminals on the
motor unit: white to white and white/red to red (Figure 2).

6. Reconnect power.

NOTE:

If you have any trouble with the operation of the

buttons, loosen the top mounting screw.

LOC

K

LIGH

T

Strip 

w

ire 7/16"

7/16" (11 mm)

Red

Grey

W

hite

Q

u

ick-Connect

Terminals

Antenna 

To release 

w

ire, p

u

sh in 

ta

b

 

w

ith scre

w

dri

v

er tip

Door Control
Connections

P

u

sh Bar

Light 
B

u

tton

Lock
B

u

tton

Door
Control
Terminal
Scre

w

s

(BACK 

V

IE

W

)

W

2

R
1

2-Cond

u

ctor

Bell 

W

ire

LOCK

LOCK

To prevent possible SERIOUS INJURY OR DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires. 
To prevent possible SERIOUS INJURY OR DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach of

children at a minimum height of 5' (1.5 m), and away from ALL
moving parts of door.

• NEVER permit children to operate or play with door control

push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is properly

adjusted and there are no obstructions to door travel.

• ALWAYS keep garage door in sight until completely closed.

NEVER permit anyone to cross path of closing garage door.

WARNING

CAUTION

WARNING

WARNING

Figure 2

Models 398LM & 398LMC 

LCD Motion Detecting Door Control Console

OWNER’S INSTRUCTIONS

PRE-WIRED INSTALLATION

REMOVE & REPLACE COVER

To Replace Insert 
Top Ta

b

s First

P

u

sh Bar Co

v

er

24 

V

olt Bell 

W

ire

LOCK

LIGHT

LOCK

LIGHT

Figure 1

1

Содержание LiftMaster 398LM

Страница 1: ...ing plastic housing Do NOT overtighten Replace cover by inserting top tabs first and then snap cover in place 4 For standard installations ONLY Run bell wire up wall and across ceiling to motor unit Use insulated staples to secure wire in several places Do NOT pierce wire with a staple creating a short or open circuit 5 Strip 7 16 11 mm of insulation from end of bell wire Connect bell wire to the ...

Страница 2: ...ll come on for five minutes then shut off This feature works by detecting body heat To disable this feature push the motion sensing button on the side of the door control We recommend that you disable the motion sensor when using the opener lights as working lights Otherwise they will turn off automatically if you are working beyond the sensors range Motion Sensing On Off Prog Learn Hour Minute La...

Страница 3: ...e door 4 When the motor unit lights blink it has learned the code If light bulbs are not installed two clicks will be heard To Add or Reprogram a Remote Control NOTE This method requires two people if the Keyless Entry is already mounted outside the garage LOCK LIGHT TO ADD ADDITIONAL REMOTE CONTROLS USING THE LCD CONTROL CONSOLE USING THE LCD CONTROL CONSOLE LOCK LIGHT LOCK LIGHT LOCK LIGHT To Er...

Страница 4: ...as been pressed on the Control Console Pressing the Prog LEARN button again will allow the user to program an additional remote control to the opener Meaning This message will appear when the Prog learn button has been pressed a second time on the Control Console or anytime on the opener The opener is ready to program another remote control by simply pressing the remote control button Once the ope...

Страница 5: ......

Отзывы: