background image

DIAL CODE SERIES

O

W

N

E

R

S

 

M

A

N

U

A

L

Telephone entry systems with two line large LC or VF displays

www.chamberlain.com

VISIT US ON THE WEB

with

surge suppression 

BUILT-IN

Содержание Dial Code

Страница 1: ...DIAL CODE SERIES O W N E R S M A N U A L Telephone entry systems with two line large LC or VF displays www chamberlain com VISIT US ON THE WEB with surge suppression BUILT IN ...

Страница 2: ... Basic Wiring Diagram 15 Postal Lock Installation 16 RS485 Connections 17 19 Memory Card Installation 20 Viewing Software Version 20 Warning and Precautions 21 Programming the Processor 22 Selecting Program Mode 23 Resident Information 24 Transmitter Card Programming 25 Area Codes 26 Utility Codes 27 Password 28 Clock Timer 29 31 Strike Time 32 Talk Time 32 Greeting 33 Volume Adjustment 33 Back Up...

Страница 3: ...le removable SRAM memory has unlimited write cycles unlike EEPROM Non Volatile Real Time Clock Calendar High quality voice communication system with back ground noise filtering Voice messages digital to help guide user Volume control via software Non Volatile PCMCIA memory card Two 2 slots for PCMCIA memory cards Double box with built in full keyboard for data processing By pressing 9 for gate or ...

Страница 4: ...e vehicular entrance gate Use the keys to scroll up and down through the names listed in the Telephone Entry System s electronic directory as shown in fig c The names are listed in alphabetical order by last name When the desired name is found enter the corresponding 3 digit code The system will dial the number assigned to the resident code entered fig d After connecting the screen will display th...

Страница 5: ...he screen will display Access Granted fig a and access will be allowed If an incorrect keycode is entered the system will inform the user of the invalid entry fig b The resident can then re enter their keycode RESIDENT USE 4 LC VF Page USING KEYCODES AND UTILITY CODES ACTIVE ENTRY 1 ONLY ACCESS GRANTED Please Enter fig a ACCESS GRANTED Please Enter fig c INVALID ENTRY Invalid 6 Digit Code fig b AC...

Страница 6: ...POWER Mounting Holes 4 Processor Key Release Lock Processor Unit Dialing Keys Programming Keys Parallel Port LC Display Memory Card Slot Memory Card Memory Card Release Buttons Processor Power Switch Microphone Postal Lock Setup External Speaker Stainless Steel Door Display Window External Keypad Key Lock Surge Suppressor Terminal Board ...

Страница 7: ...LING KEYS LIGHT Lights up dialing keys for easy visibility PHONE DIALING KEYS Used to dial residents keycodes SCROLL KEYS Scrolls through names in alphabetical order on screen UNLOCK KEY Residents and utility personnel use this key with their key code to open gate HANG UP KEY Pressed when user wants to hang up ACCESS FOR POSTAL LOCK 16 GAUGE STAINLESS STEEL DOOR Heavy duty and weather resistant 1 ...

Страница 8: ...emory Card Slot Memory Card Memory Card Release Buttons Processor Power Switch Microphone Postal Lock Setup Surge Suppressor Terminal Board External Speaker Stainless Steel Door Display Window Display Hood External Keypad Key Lock 7 LC VF Page VF ENTRY PHONE FEATURES INSIDE All components and specifications are subject to change without notice ...

Страница 9: ...ns and direct sunlight DIALING KEYS LIGHT Lights up dialing keys for easy visibility PHONE DIALING KEYS Used to dial residents keycodes SCROLL KEYS Scrolls through names in alphabetical order on screen UNLOCK KEY Residents and utility personnel use this key with their key code to open gate HANG UP KEY Pressed when user wants to hang up ACCESS FOR POSTAL LOCK 16 GAUGE STAINLESS STEEL DOOR Heavy dut...

Страница 10: ...ns no longer needed ENTER KEY Registers information into memory after it is typed HELP KEY Helps user while in programming or user modes SCROLL KEYS Scrolls through screens menus KEYBOARD Works like standard keyboard to type in information and names PHONE JACK RJ11 Connects to surge suppressor terminal board INPUT OUTPUT CONNECTOR Connects to Surge Suppressor terminal board COMMUNICATION PORT Conn...

Страница 11: ...om the Processor Containment Box and bolt the Processor Containment Box to the recess in the wall using the four mounting holes Feed the power and phone lines through the knockout in the back of the box to make all wire connections NOTE Be sure to install the unit at normal eye level Be sure to read and follow all Chamberlain Elite instructions before installating and operating any Chamberlain Eli...

Страница 12: ...ounting holes Feed the power and phone lines through the knockout in the back of the box to make all wire connections NOTE Be sure to install the unit at normal eye level 7 16 1 4 1 4 1 8 1 2 1 2 3 4 3 4 8 1 4 6 7 8 It is MANDATORY that his un t is properly grounded The prov ded chass s g ound wire must be connec ed to he ground rod If unit is not grounded lightning damage wi l occur Please refer ...

Страница 13: ...ding of all access to facility POSTAL EXIT SW INPUT For allowing postal lock access to pedestrian gate or door Activates gate relay using gate strike time CHASSIS GROUND Entry Phone MUST be properly grounded Refer to Grounding the Unit and Earth Ground Rod Installation sections POWER LED Indicates Phone system has 12 Vac power GATE RELAY LED Indicates gate relay is activated DOOR RELAY LED Indicat...

Страница 14: ... VCR RELAY It is MANDATORY that this unit is properly grounded The provided chassis ground wire must be connected to the ground rod If unit is not grounded lightning damage will occur Please refer to the owners manual for proper grounding instructions MADE N USA eliteentryphone com Refer to the next page for ground rod installation It is MANDATORY that this unit is properly grounded The provided c...

Страница 15: ...r consult the local code Proper grounding gives an electrical charge such as from an electrical static discharge or a near lightning strike a path from which to dissipate its energy safely into the earth Without this path the intense energy generated by lightning could be directed towards the Telephone Entry System TES Although nothing can absorb the tremendous power of a direct lightning strike p...

Страница 16: ...e Gate 7 day timer or ElitePro remote programming software Connect two wires to the secondary gate or door The door relay will be activated by either pressing 5 on the resident s phone Door 7 day timer or ElitePro remote programming software 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 85 Ft 140 Ft 225 Ft 350 Ft 560 Ft 12 Vac 50 VA Maximum Distance Wire Gauge RING TIP Entry 2 Door Relay Terminal Connection ...

Страница 17: ...ed by application to your local post office Open the front panel of the Telephone Entry System and remove the hole plug Retain nuts and washers Install the postal lock with the sliding bolt oriented away from the speaker Install the enclosed plate end switch assembly over the sliding bolt so that when the bolt is extended it will activate the switch as shown in the diagram Fasten by using the encl...

Страница 18: ... Device ID Number set by using the rotary switches on the device Refer to specific RS485 Instruction sheets Turn Terminator Switch ON for Last Device on Wire Run Turn Terminator Switch ON for Last Device on Wire Run Turn Terminator Switch ON for Last Device on Wire Run Turn Terminator Switch ON for Last Device on Wire Run Turn Terminator Switch ON for Last Device on Wire Run Turn Terminator Switch...

Страница 19: ...nit is not grounded lightning damage will occur Please refer to the owners manual for proper grounding instructions MADE IN USA eliteentryphone com RS485 Card Release Button Main Me Card Slot RS485 Memory Card Slot NOTE To support RS485 devices you must insert the RF communicator card in the RS485 memory card slot BEFORE turning on the processor Elite Entry Phone COMMUNICATOR CARD Remote Access RS...

Страница 20: ...f unit is not grounded lightning damage will occur Please refer to the owners manual for proper grounding instructions MADE IN USA eliteentryphone com RS485 Card Release Button Main M ard Slot RS485 Memory Card Slot NOTE To support RS485 devices you must insert the RF communicator card in the RS485 memory card slot BEFORE turning on the processor Elite Entry Phone COMMUNICATOR CARD Remote Access R...

Страница 21: ...ion screen is accessible on all Dial Code systems for easy reference Turn power off and insert Memory Card in Main Memory Slot Turn power on and the information screen should display as seen in fig e If the screen continues to display the Insert Memory Card screen fig c then eject memory card by pressing the corresponding release button down and reinsert Memory Card into main slot fig d Otherwise ...

Страница 22: ...ose the Processor Unit or the open Processor Containment Box to rain snow or harsh weather conditions Do not drop the Processor or expose it to impact Do not touch the terminals on the RAM Cards Do not bend drop or expose to impact C V B N M X Z A Q W E R T Y U I 0 7 4 1 2 3 5 6 8 9 O P S D F G H J K L SPACE BAR EX T HELP PROG RAM ERASE ENTER BACK SPACE SHIFT ...

Страница 23: ... the button is pressed the screen will display If you enter the wrong password the screen will prompt you to try again Press to retry entering your password Press to quit the programming menu TO ENTER PROG MODE Type Password ____ Type in the factory present password 7777 Press The Program Selection Screen will display SELECT PROG MODE N Names U Utility INVALID PASSWORD R Retry EXIT Quit R Pressing...

Страница 24: ...1 page 32 page 32 page 33 page 33 page 34 Program or edit Resident Names Program or edit Utility Codes Program New Password recommended Program System Clock and Seven Day Timers Program relay output time for 2 relays Program length of Talk Time Program custom Welcome Screen Message Program Volume level Backup of memory card 1 2 3 4 5 6 7 8 9 N U P C S T G V B Use the keys to scroll through the nin...

Страница 25: ...ame press the key and the first empty code will display N To program by code enter a three digit code and press the key Assignment of Resident Key Codes is optional The first three digits of the Key Code is the assigned Directory Code Assign the last three digits numeric characters only to create an individual Key Code If using the RF Card proceed to Step 6 fig e Press the key STEP 5 To view or ed...

Страница 26: ...time zones and restrictions associated with transmitter card codes can only be programmed remotely using the EMS modem software STEP 8 C V B N M X Z A Q W E R T Y U I 0 7 4 1 2 3 5 6 8 9 O P S D F G H J K L SPACE BAR EX T HELP PROGRAM ERASE ENTER BACK SPACE SHIFT STAND ALONE RECEIVER Model ERRB485 Processor Touch the card to the card reader to activate remote device Model ECR485B Press button on t...

Страница 27: ...needed press while in the prefix field Then type the required number of digits in the area code field followed by the phone number Press the key to continue with the entry as described in the Resident Information section AREA CODES 26 LC VF Page To erase Resident information press the key Press the key for assistance fig a 005 PHONE NUMBER _ ___ ___ ____ fig b 005 PHONE NUMBER 1 ___ ___ ____ PREFI...

Страница 28: ... in the screen that follows and press the key or fig c A 4 digit Utility Code numeric characters only may be assigned to Utility Companies such as delivery telephone construction companies water power etc These utilities can use their individual code to access the premises within the time zone that you program Each system no matter what the memory capacity is equipped with 60 available Utility Cod...

Страница 29: ...e transaction PASSWORD 28 LC VF Page SELECT PROG MODE P Password NEW PASSWORD RE ENTER PASSWORD The factory present password is 7777 We suggest that you customize it In the Program Selection Screen fig a Press the key P Always remember your password This password is required to enter the Program Mode If you lose your password you will need to contact the manufacturer to reissue a new password fig ...

Страница 30: ...T PROG MODE C Clock Timer PROG CLOCK TIMER 1 Date Time PROG CLOCK TIMER 2 Gate Timer PROG CLOCK TIMER 3 Door Timer DATE 02 11 2000 Time 07 31am p pm Today Is THURSDAY Use To Select Day Daylight Savings y Y Yes N No In the Program Selection Screen fig a Press the key C Use the keys to scroll between the three different menu choices fig b Select the number of your choice or press the key while on th...

Страница 31: ...00am 05 00pm fig a SUN G Tmr2 ON F off 07 00am 05 00pm SAT G Tmr1 ON F off 07 00am 05 00pm SUN G Tmr1 ON F off 07 00am 05 00pm fig c fig b MON G Tmr1 ON F off 08 00am 04 30pm USE ARROWS TO VIEW PROGRAM INDIVIDUAL TIME ZONES See next page for instructions To program the second timer repeat the above procedure Press the key when complete Press to program Gate Timers Menu Press to program the Door Ti...

Страница 32: ... n Fri n Sat n Setup New Timers N View Edit Timers Press to program Gate Timer Menu Press to program the Door Timers Menu 2 3 See previous page for instructions To program the second timer repeat the above procedure Press the key when complete To exit Timers screen press the key Press the key for assistance IMPORTANT NOTE While in the help screens programming will be disabled To continue programmi...

Страница 33: ...t for both gates and doors fig b For either the Gate or Door Strike TIme you may now type in a name and location up to 13 characters to which you want the programmed strike time applied fig e and fig f Press the key to complete the transaction Press the key to set the Door Strike Time Type in a time from 1 to 99 seconds fig c Press the key to enter your selection D Press the key to set the Gate St...

Страница 34: ...y Use the keys to adjust the volume to the desired level fig d Press the key to complete the entry Volume at unit speaker for visitor tenant communication V fig c CALL VOLUME ___________ fig d Use the Volume Screen to adjust both call and unit message volume levels Pressing the button will provide users with a help message IMPORTANT NOTE While in the help screens programming will be disabled To co...

Страница 35: ...when the cards were last updated fig c and fig d Use the keys to scroll through the information SELECT PROG MODE V Volume B Backup fig b fig c BACKUP Card Updated 02 11 01 04 20am fig d ENTER To Backup EXIT To Quit fig e In the Program Selection Screen fig b Press the key Insert additional memory card in the Backup Slot B fig a Pressing the button will provide users with a help message IMPORTANT N...

Страница 36: ... of the display fig b An alert beep will accompany this icon The batteries must be charged to continue LOW BATTERY ICONS If a battery icon appears in the top right corner of the display and the letter next to it is an M or a C as shown in fig d and fig e contact Manufacturer for instructions If the battery backup level reaches it s minimal charge an error message will display fig c and the system ...

Страница 37: ...ction Terminal T020 LC Complete Internal Metal Box Processor Box T025 Programming Keys T026 Postal Lock Assembly T027 LCD Processor No Memory Card T029 Key for Internal External Lock T030 LCD Display T031 Kit for Keypad Light T032 Phone Control Board Inside Processor LC Part LC Description T025 T020 T044 T032 T033 LCD Display Window T035 LC External Box Assembly T036 Heater Pad Option Pre Installe...

Страница 38: ...in Comm Port Connector Surge Protection Terminal T014SPT External Box Connection Kit Surge Protection Terminal T018 Vacuum Florescent Display T019 VF Complete Internal Metal Box Processor Box T025 Programming Keys T026 Postal Lock Assembly T028 VFD Processor No Memory Card T029 Key for Internal External Lock T031 Kit for Keypad Light T032 Phone Control Board Inside Processor T034 VF External Box A...

Страница 39: ... as prescribed in the appropriate Terminal Equipment Technical Requirements document s The department does not guarantee the equipment will operate to the users satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using a acceptable method of connection...

Страница 40: ...845 Larch Avenue Elmhurst Illinois 60126 1196 114A2866F 2008 The Chamberlain Group Inc All Rights Reserved ...

Отзывы: