FAULT LIST
The following conditions can cause a fault in the BG 3000-B1 gate operator system:
1.
Interrupt Bar activation.
2.
Average motor overcurrent
(overload) caused by an excessive motor current.
3.
Instantaneous motor overcurrent
(left/right reverse sense) due to an impact on the gate.
4.
Maximum motor run time
exceeding 75 seconds.
5.
Inoperative motor
caused by an open motor winding, broken or unconnected input motor
wires, or thermal overload.
6.
Limit switch staying closed when gate is supposed to move
, caused by a broken V-belt,
defective limit switch, or defective cams.
Faults 1, 2 and 3 may be cleared at any time by the following,
if Fault Re-Try is ON:
•
All open commands (Open, Radio, Exit, Fire)
•
Manual commands (Open, Close, Stop)
Faults 1, 2 and 3 may be cleared at any time by the following,
if Fault Re-Try is OFF:
•
Fire
command
•
Manual commands (Open, Close, Stop)
•
All other commands must wait 60 seconds to clear these faults.
Faults 4, 5 and 6 may be cleared at any time by the following:
•
All open commands (Open, Radio, Exit, Fire)
•
Manual commands (Open, Close, Stop)
C.
FAULTS AND THEIR CAUSES
1. IF FAULT AND OVERLOAD LED’S ARE TURNED ON
1. OVERLOAD ajustment is set too low (factory setting is at the 3:00 o’clock position).
2. Bad Control board.
3. Bad
motor.
2. IF FAULT AND REVERSE LED’S ARE TURNED ON
1. REVERSE or INRUSH adjustment is set too low.
2. The gate is blocked by an object.
3. Frozen motor or gearbox.
4. The Maglock does not disengage from the gate at the start of gate opening.
5. Power Fail option was installed without readjusting the gate sensitivity adjustments.
6. A sudden increase in input power.
7. Bad Control board.
8. Belt is too tight.