background image

1

INTRODUCTION

The Chamberlain Garage Power Station gives you the convenience of 
power, air, and lighting directly within your reach. It mounts neatly to 
your ceiling or wall and reaches anywhere in the garage with a 25 foot 
cord! The Chamberlain Garage Power Station’s smart design will turn 
your garage into an efficient work area.

SPECIFICATIONS

Voltage

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  120 Vac

PSI Rating

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 psi max pressure

Hose

 . . . . . . . . . . . . . . . . . . . . . . . . 25 foot 1/4" OD polyurethane hose

Locking tire chuck and pressure gauge

Extension Cord

 . . . . . . . . . . . . . . . . . . . . . . . . .  25 feet SJTW 16 AWG

Amps

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Inflator

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .switches on below 80 psi, 

switches off at 100 psi

Task Light Bulbs

 . . . .GU10 120 V Halogen bulbs (50 watts maximum)

Auto Shutoff

GARAGE POWER STATION

MODEL A7008890

IMPORTANT SAFETY INFORMATION

To reduce the risk of SERIOUS INJURY or DEATH:
•  READ AND FOLLOW ALL INSTALLATION WARNINGS AND 

INSTRUCTIONS.

•  FOR INDOOR USE ONLY. 
•  To avoid SERIOUS PERSONAL INJURY or DEATH from 

electrocution, disconnect ALL electric power BEFORE performing 
ANY service or maintenance. 

•  DO NOT OVERLOAD RECEPTACLE. Maximum current is 10 amps.
•  DO NOT immerse cords, plugs or product in water or other liquid. 
•  DO NOT operate appliance with a damaged cord or plug or after 

the appliance malfunctions or has been damaged in any way. 
Return appliance to nearest authorized service facility for 
examination, repair or adjustment. 

•  The use of accessory attachments NOT recommended by the 

appliance manufacturer may result in fire, electric shock or 
INJURY to persons. 

•  DO NOT let inflator head touch hot surfaces.
•  DO NOT use appliance for other than intended use. 
•  Connect to a properly grounded outlet.  
•  DO NOT use a 3 – 2 prong adapter. 
•  DO NOT use above hazardous locations or areas where water can 

accumulate or in rain or mist.

•  NEVER USE the inflator as a toy. 
•  NEVER permit children to operate or play with the Garage Power 

Station. KEEP OUT OF REACH OF CHILDREN.

•  Keep inflator away from flammable areas/liquids at ALL times. 
•  DO NOT handle work light or try to plug something into receptacle 

when your hands are wet or when standing on a wet or damp 
surface. 

•  This appliance MUST ALWAYS BE USED in accordance with all 

local electrical and building codes. 

To avoid personal INJURY or DAMAGE to property and to reduce the 
risk of electric shock and fire:
•  DO NOT use this cord reel in explosive atmospheres, near 

flammable liquids or where explosion proof equipment is required. 

•  DO NOT direct air stream at body. 
•  Use ONLY recommended air-handling parts acceptable for air 

pressure. 

•  DO NOT over-inflate. 
•  This inflator is designed to inflate car tires, ATV tires, motorcycle 

tires, bicycle tires, sports equipment, air mattresses, beach toys 
and other inflatables. 

•  Allow inflator to cool down 10 minutes after each 10 minutes of 

continuous use. 

•  Use safety glasses. Use facemask or dust mask if operation is 

dusty. 

•  DO NOT allow cord reel to retract the cord by itself as DAMAGE or 

INJURY may occur from excessive rewind speed. 

•  BEFORE cleaning product, unplug from the power source. 
•  DO NOT use solvents such as gasoline, turpentine, etc. to clean 

unit. Keep cord reel clean to assure smoothest operation. To clean, 
simply pull cord to its full length and allow to retract through a 
dampened rag. DRY thoroughly before plugging back into outlet. 

•  PULL out cord to full length when using the receptacle. 
•  The Garage Power Station MUST be RIGIDLY fastened to 

structural support on wall or ceiling.

•  Disconnect ALL electrical power BEFORE replacing bulbs.
•  Use ONLY 50 watt or smaller bulb.
•  For Light Duty Use Only.

CARTON INVENTORY

Garage Power Station 

Rubber Isolator - large (2)

¼" x 2 ½" Lag Screws (2)  

Rubber Isolator - small (2)

Washer (2)

Содержание A7008890

Страница 1: ...e or in rain or mist NEVER USE the inflator as a toy NEVER permit children to operate or play with the Garage Power Station KEEP OUT OF REACH OF CHILDREN Keep inflator away from flammable areas liquids at ALL times DO NOT handle work light or try to plug something into receptacle when your hands are wet or when standing on a wet or damp surface This appliance MUST ALWAYS BE USED in accordance with...

Страница 2: ...g plate TOOLS Tape measure Stud finder Pencil or marker Drill 3 16 Drill bit 3 Phillips screwdriver 7 16 socket wrench 6 socket extension optional Small flathead screwdriver 5 Place a washer and small rubber isolator on each lag screw Insert each lag screw through the mounting holes of the mounting plate 6 Place a large rubber isolator on each of the lag screws behind the mounting plate 7 Position...

Страница 3: ...nflation accessory into the desired object to be inflated 3 Pull the hose out of the retainer on the side of the work light assembly 4 Press the lever on the quick connect locking tire chuck valve and push over the end of the inflation accessory 5 Release the lever to lock onto the inflation accessory The object will immediately start to inflate 6 Monitor the pressure gauge on the back of the work...

Страница 4: ...LIMITED TO ABUSE MISUSE UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT REPLACEMENT OF CONSUMABLE ITEMS E G FLOOD LAMPS OR UNITS INSTALLED FOR NON RESIDENTIAL USE THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH OR RELATING TO STUD FRAMING OR CEILING TRUSSES THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INT...

Отзывы: