Step 3:
(Illustration 3). Thread the bell wire through
completed hole from inside the garage. Fasten wire to
the Key Switch terminal screws before attaching
mounting plate to jamb. In most cases, 4 screw nails will
hold the plate firmly in place. Drive a nail into jamb and
wind some wire around it before running wire to the
opener terminals.
NOTE: Instructions for attaching bell wire to opener
terminals are on Page 2.
CAUTION: Bell wire should be pulled taut to prevent
access to wiring from outside the garage.
Step 2:
(Illustration 2). If your garage has a built-up jamb,
drill the hole to a depth of 2" (5 cm). Then on the inside
jamb, drill a second hole into the first hole to complete
access.
(3)
Bell Wire
Terminal
Screw
Nail
Mounting
Plate
Step 1:
Disconnect power to operator. (Illustration 1)
Position key Switch in the upper half of garage door jamb.
Mark the location on horizontal center of jamb or to a
depth of 2" (5 cm) (see Step 2).
Step 4:
If screw nails won’t hold the plate firmly in place,
use anchor and nut supplied with hardware. (See
illustration on page 2). If anchor and nut are used,
remove the Key Switch terminal screws.
Insert key Switch in drilled hole. Install anchor and nut.
Return screws to switch terminals. Fasten bell wire to
terminals. Drive a nail into jamb and wind some wire
around it before connecting to terminals on back of
opener.
NOTE: Instructions for attaching the bell wire to opener
are on page 2 (illustration 5).
1
KEY SWITCH INSTALLATION INSTRUCTIONS
FOR SECTIONAL DOORS
(FOR ONE-PIECE DOORS Refer to Page 2)
(1)
Garage
Exterior
Door Jamb
(2)
1" (2.5 cm)
Diameter
Hole
2" (5 cm) Min.
Door
Jamb
Door
Track
To prevent possible SERIOUS INJURY or DEATH from electrocution,
disconnect power to opener BEFORE proceeding.
WARNING
CAUTION
WARNING
WARNING