1

A

B

C

C

D

F

E

G

Logic Board  

Model 050DCRJWFMC

WARNING:

 This product can expose you to chemicals 

including lead, which are known to the State of California to 

cause cancer or birth defects or other reproductive harm. 

For more information go to www.P65Warnings.ca.gov.

To prevent possible SERIOUS INJURY or DEATH:
•  Disconnect ALL electric and battery power BEFORE performing ANY 

service or maintenance.

To prevent damage to the receiver/logic board, DO NOT touch printed 

circuit board of replacement receiver/logic board during installation.
ALWAYS wear protective gloves and eye protection when changing the 

battery or working around the battery compartment.

NOTICE: 

This device complies with Part 15 of the FCC rules and Industry Canada’s license-

exempt RSSs. Operation is subject to the following two conditions: (1) this device may not 

cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance 

could void the user’s authority to operate the equipment.
This device must be installed to ensure a minimum 20 cm (8 in.) distance is maintained between 

users/bystanders and device.
This device has been tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC rules and Industry Canada ICES standard. These limits are 

designed to provide reasonable protection against harmful interference in a residential 

installation. This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is encouraged to try to 

correct the interference by one or more of the following measures:
•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

•  Consult the dealer or an experienced radio/TV technician for help.

Before you begin. 

Your new MyQ

®

 serial number is located on the 

replacement label with your replacement logic board. You will need this new MyQ 

serial number to connect your opener to the network.

 

1.

  Disconnect power.

 2. 

Open the front panel 

(A)

 

3.

  Remove the battery cover. 

Disconnect the battery. Remove 

the battery and set aside 

(B)

.

 

4.

  Add the Step Saver sticker under 

the yellow program button. 

 

5.

  Add the Step Saver sticker under 

the yellow program button. 

Disconnect the wires coming from 

the safety reversing sensors,door 

control, door lock and cable 

tension monitor from the logic 

board (C).

 

6.

  Remove the receiver logic board 

cover 

(D)

.

 

7.

  Disconnect all the wiring harnesses 

from the logic board 

(E)

.

 

8.

  Remove the four screws securing 

the logic board. Rmove the logic 

board 

(F)

, and discard.

 

9.

  Install the new logic board and 

connect the wiring harnesses. 

Route the antenna through the 

channel in the cover.

 

10.

  Adhere the new MyQ serial 

number label over the original 

label on the logic board cover.

 

11.

  Reprogram the travel and test the 

safety reversal system (see pages  

and 3).

12.

  Program all remote controls and 

keyless entries (see page 4)..

13.

   Use the MyQ app to add the 

new MyQ serial number to your 

account.

Содержание 050DCRJWFMC

Страница 1: ...ctions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reor...

Страница 2: ... both the up and down positions have been manually set the Safety Reversing Sensors will reconnect and become operational Then the opener will enter a force sensing operation by automatically moving the door open and close The garage door opener will sound an audible and visual alert before automatically opening and closing the door The garage door opener will beep three times confirming that the ...

Страница 3: ...ivated the UP and DOWN arrows will flash diagnostic code 3 5 will activate the garage door opener Test the Automatic Garage Door Lock 1 With the garage door fully closed the automatic garage door lock bolt should be protruding through the track 2 Open the garage door The automatic garage door lock should retract before the garage door begins to move 3 Close the garage door When the garage door rea...

Страница 4: ...ou wish to operate your garage door 5 Keyless Entry Enter a 4 digit personal identification number PIN of your choice on the keyless entry keypad Then press the ENTER button The garage door opener lights will flash or two clicks will be heard when the code has been programmed Repeat the steps above for programming additional remote controls or keyless entry devices If programming is unsuccessful p...

Страница 5: ...sé conformément aux instructions peut causer un brouillage nuisible aux communications radio Cependant rien ne garantit l absence de brouillage dans une installation particulière Si cet équipement cause un brouillage nuisible à la réception radio ou télévisée ce qui peut être déterminé en éteignant et en rallumant l équipement l utilisateur est invité à tenter de corriger le brouillage en prenant ...

Страница 6: ... de dégagement Réglage automatique de la force Lorsque la position ouverte et la position fermée sont réglées manuellement les capteurs d inversion de sécurité fonctionneront L ouvre porte entrera un fonctionnement de capteur de force en ouvrant et fermant la porte automatiquement Avant d ouvrir et de fermer la porte automatiquement l ouvre porte de garage émettra une alerte audible et visible L o...

Страница 7: ... vers le bas clignoteront le code de diagnostic 3 5 l ouvre porte de garage s activera Effectuez un test de la serrure automatique de porte de garage 1 Lorsque la porte de garage est complètement fermée le pêne du verrou automatique de porte de garage doit dépasser du rail 2 Ouvrez la porte de garage La serrure automatique de la porte de garage devrait se désengager avant que q la porte de garage ...

Страница 8: ...s fil Introduire un numéro d identification personnelle NIP à quatre chiffres de son choix sur le pavé numérique Appuyer ensuite sur le bouton ENTER entrée L éclairage de l ouvre porte de garage clignote ou deux déclics se font entendre une fois que le code a été programmé Répétez les étapes ci dessus pour la programmation des télécommandes supplémentaires ou des dispositifs d émetteur mural à cod...

Страница 9: ...trucciones podrá causar interferencia con comunicaciones radiales Aun así no hay garantía de que no se produzcan interferencias en una instalación particular Si este equipo produce interferencia en la recepción de radio o televisión lo cual puede determinarse apagando y encendiendo la unidad el usuario debe tratar de corregir el problema por medio de lo siguiente Volver a orientar o reubicar la an...

Страница 10: ...ajo se hayan establecido manualmente los sensores de seguridad de reversa volverán a conectarse y a funcionar Luego el operador entrará en una operación de detección de fuerza al mover automáticamente la puerta para abrirla y cerrarla El operador de puerta emitirá una alerta sonora y visual antes de abrir y cerrar la puerta automáticamente El operador de puerta emitirá tres pitidos para confirmar ...

Страница 11: ...ntado a ras con la pared y que el rodillo quede libre de cualquier tipo de obstrucciones Si se activó el monitor de tensión del cable las flechas UP y DOWN parpadearán el código de diagnóstico 3 5 y se activará el abrepuertas de garaje Probar la cerradura automática para puertas de garaje 1 Con la puerta de garaje completamente cerrada el pestillo de la cerradura automática de la puerta debe sobre...

Страница 12: ... dígitos PIN como código personal de uso del teclado digital de acceso Pulsar el botón ENTER Las luces del abre puerta se encenderán intermitentemente o se escucharán dos clic cuando el código quede programado Repetir los pasos anteriores para programar otros controles remoto o teclados digitales de acceso Si no puede programar uso el botón de Aprendizaje para programar el control remoto Programar...

Отзывы: