Chalmit 844I Скачать руководство пользователя страница 1

 
 
 

 

 
 

I-800I-01.doc  

Issue 

06 

  November 

2013

   

 

 

 

 

 

 

 

 

                                              IOM – 

844I, 854I & 864I - SS FLOODLIGHTS (IND) 

 

 

 

 

Issue 06

 

 

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS  

800 Series - Stainless Steel Floodlight Luminaires

Industrial Models 844I, 854I, & 864I

 

 

 

 

 

 

 

Important

Please read these instructions carefully before installing or maintaining this equipment. 
Good electrical practices should be followed at all times and this data should be used  
as a guide only. 

 

 
 
 
 
 
 

 

C C 

3 HOLES ø13 (854, 864)

 

    2 OFF M20 CABLE ENTRIES

 

DIMENSIONS

844I

70/100W

854I

 

150/250/400W

 

864I

 

400/600W

A
B
C
D
E

F

415

 

415

 

630

 

150

 

490

 

185

 

260

 

308
443

75

348
175
175

465

 

615

 

150

 

500

 

190

 

250

 

3 HOLES ø12 (844)

 

Содержание 844I

Страница 1: ...I Important Please read these instructions carefully before installing or maintaining this equipment Good electrical practices should be followed at all times and this data should be used as a guide only A E D F C C B 3 HOLES ø13 854 864 2 OFF M20 CABLE ENTRIES DIMENSIONS 844I 70 100W 854I 150 250 400W 864I 400 600W A B C D E F 415 415 630 150 490 185 260 308 443 75 348 175 175 465 615 150 500 190...

Страница 2: ...ools Suitable spanners for installing cable glands 3mm and 5mm flat blade screwdriver Pliers knife wire strippers cutters 3 3 Electrical Supplies The supply voltage and frequency should be specified when ordering A maximum voltage variation of 6 6 on the nominal is expected In some cases the luminaires have multi tapped control gear which can be set to a range of 50 and 60Hz and voltages of 220 23...

Страница 3: ...material or suitably protected to meet any prevailing environmental conditions Plastic glands may be used except in cases where the earth is provided by means of the cable armour in which case a suitable metal gland should be employed Care should be taken to ensure that a good contact is made between the gland and the body of the luminaire It is the responsibility of the user to ensure that an ade...

Страница 4: ...fter switch on to normal after 4 minutes rectification effects caused by asymmetrical cathode heating for a few seconds after starting this effect is random and very variable With the availability of MCBs with a wide range of characteristics the individual engineer can make a better judgement of what is required The normal capacitor current will probably be the determining factor 0 076A per F at 2...

Страница 5: ... 30 C to 50 C 400W MBI 4 0 8 0 2 2 4 4 40 445 30 C to 50 C Table 2 Fuse Ratings Refer to Section 5 0 Lamp Wattage Number of Lamps 1 2 3 4 5 6 70W 4A 4A 4A 4A 4A 4A 100W 4A 4A 6A 10A 10A 10A 150W 4A 6A 10A 10A 16A 16A 250W 10A 16A 16A 20A 20A 20A 400W 16A 20A 20A 25A 25A 32A 600W 16A 20A 25A 32A 32A 40A Note Minimum Power Correction Factor 0 85 Catalogue Ref Lamp Gear Voltage Operating Temperature ...

Страница 6: ...I 800I 01 doc Issue 06 November 2013 6 IOM 844I 854I 864I SS FLOODLIGHTS IND ...