SL04B Instructions Rev01
MODEL: SL04B
We are delighted that you have purchased this PIR Light. This light
is suitable for indoor or outdoor use. Please read this instruction
manual before installation and retain for future reference.
IMPORTANT: Never modify the unit, there are no user serviceable
parts inside. Not suitable for use with dimmer switches. Install in
accordance with IEC Wiring Regulations.
THE LIGHT SHOULD BE INSTALLED BY A QUALIFIED
ELECTRICIAN.
OCCUPANCY
The PIR Sensor has an Occupancy Range of Radius 3 meters. In this
range, the sensor will detect small movement.
If you want to achieve best results, we suggest you take into account the
following points:
1. The Occupancy Range is 3 meters.
2. We suggest the delay time must be set more than 10 minutes.
3. The PIR Sensor must worked at 25˚c or lower and dry weather
(normal temperature)
POSITIONING THE LIGHT
When selecting the mounting position, take into account the
following points:
1.
The sensor is designed for optimum performance when mounted at a
height of between 1.8.5 to 2.5 meters (see Figure 1)
2.
Avoid pointing at or positioning close to heat sources such as heaters
or heat extraction units, which may cause false triggering.
3.
Avoid pointing at bright lights as the PIR sensor will not function when
you set Lux control level to dark ( position).
4.
Avoid mounting at strong electromagnetic disturbance, i.e. near
electrical motor or fluorescent lamp ballast.
INSTALLING THE LIGHT
Before commencing any electrical work, ensure the mains supply is
isolated by switching off and removing the relevant fuse. (See Figure
2 A ,B and C)
A.B. Wall and Ceiling Mounting(Figure 2A and B)
1. Use a screwdriver to remove the bottom
2. Remove the Junction Box and Terminal Block
3. Use the Bottom Cover to mark the position of screw holes onto
mounting surface. Drill the wall to depth of about 35mm and fit the
plastic plugs, and then fix the Bottom Cover to the mounting surface
with rightly screws. Care should be taken to avoid drilling or screwing
into concealed electrical wiring.
Occupancy 3m
Fig.1 Detection Area
210¡ ã
1.8-2.5m
10m