Operation
To turn on the heater
1 Turn on the valve on the gas supply cylinder completely
2
Press and turn the variable control knob to PILOT position (counter-clockwise 90°),
3 Press down the variable control knob and hold for 60 seconds While holding down the
variable control knob, press the igniter button several times until the pilot flame lights,
Release the variable control knob after the pilot name lights
NOTE: lf a new tank has just been connected, please allow at least one minute for
the air in the gas pipeline to purge out through the pilot hole. When lighting the pilot
flame make sure that the variable control knob is continuously pressed down while
pressing the igniter button, Variable control knob can b e released after the pilot flame
lights. If the pilot flame does not light or it goes out, repeat step 3.
4
After the pilot flame lights, turn the variable control knob to maximum position and
leave it there for 5 minutes or more before turning the knob to desired temperature
position
Caution: check that no broken on the glass is found before operation.
To turn off the heater
1
Turn the variable control knob to PILOT position.
2 Press and turn the variable control knob to OFF position
Off: the heater stops operation
Hi: maximum temperature position
Lo: minimum temperature position
Knob
Igniter
28