Cleaning
•
Wipe off powder coated surfaces with soft, moist rag. Do not clean heater with cleaners
that are combustible or corrosive
• Remove debris from the burner to keep it clean and safe for use
• Cover the burner unit with the optional protective cover when the heater is not in use
Storage
• Always close the gas valve of the gas cylinder after use or in case of a disturbance
• Remove the pressure regulator and the hose
• Check the tightness of the gas valve and for damage If you suspect a damage, have it
changed by your gas dealer
• Never store liquid gas cylinder in a subterrain, or at places without adequate air
ventilation
Troubleshooting
Problem
Probable cause
Solution
Pilot will not light
Gas valve may be OFF
Tank fuel empty
Opening blocked
Air in supply system
Loose connections
Turn the gas valve ON
Refill LPG tank.
Clean or replace opening
Purge air from lines
Check all fittings.
Pilot will not stay
on
Debris around pilot
Loose connections
Thermocouple bad
Gas leak in line
Lack of fuel pressure
Clean dirty area
Tighten connections
Replace thermocouple
Check connections
Tank near empty. Refill LPG tank.