background image

VENT FrEE / FluElEss 

Gas FirEplacE  

iNsTallaTioN & opEraTiNG 

InstructIon Manual

Please read these instructions carefully before 

installation, use and retain them for future reference

LP GAS

VFDI 1000

These appliances conform to the requirements of SANS 1539:2017

LPGSA Permit Number: 1013-41/1-RSA-12-A

Содержание VFDI 1000

Страница 1: ...erating Instruction Manual Please read these instructions carefully before installation use and retain them for future reference LP GAS VFDI 1000 These appliances conform to the requirements of SANS 1...

Страница 2: ...S T Y LE SAF E T Y Q U A LITY THAT L A S T S CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD O CHEF Fireplace a n d W E L C O M E t o t h e CHAD O CHEF family...

Страница 3: ...ATION REQUIREMENTS 2 INSTALLATION INSTRUCTIONS 3 FOR QUALIFIED GAS INSTALLER 3 NG6801 VALVE Operating Instructions 4 NG6801 VALVE Pressure Testing 4 Checklist For Gas Installer 5 Caution 5 Warnings 6...

Страница 4: ...t is the installer s responsibility to do these calculations on behalf of the home owner 6 This appliance may only be installed by a registered LP Gas installer and must comply with the installation r...

Страница 5: ...ughts which may be generated by outside doors It is recommend that the fireplace should not be installed within 500mm of any air vent as this could affect the working of the ODS Clearances to combusti...

Страница 6: ...g up 1 Insert the burner with the venturi facing the gas jet and ensure the burner is seated correctly 2 Fill the burner with the special black radiant ceramic ash or glass chips 3 Spread the decorati...

Страница 7: ...s before repeating the ignition procedure 5 Continue turning the knob anticlockwise to the HIGH position and the main burner should light after a few seconds 6 Select the required HIGH or LOW setting...

Страница 8: ...h a 10mm gap between them DO NOT use more coals or pebbles than recommended and supplied See Page 2 The room must be bigger than the minimum room size for that fireplace See Page 2 Ensure that there i...

Страница 9: ...WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH Carbon monoxide poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the...

Страница 10: ...he biggest pests because they tend to occupy the smallest of holes which will be in the burner venturi or the pilot air holes If spiders are a problem in the home have your fireplace serviced just bef...

Страница 11: ...r This does not mean that it is rust proof it will require regular maintenance to preserve this protective surface layer in order to enjoy the high quality standard that is to be expected from Chad O...

Страница 12: ...Manufactured By Chad o Engineering PO Box 986 Honeydew 2040 Tel 011 668 1910 Email Sales chad o chef co za www chad o chef co za Version 01...