![CGEO INTERNATIONAL LIMITED CGEO-SG5 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/cgeo-international-limited/cgeo-sg5/cgeo-sg5_installation-manual_2585433011.webp)
CGEO-SG5
Rebar VW Strain Gauge 10
CGEO INTERNATIONAL LIMITED
Installation Manual
K is the thermal coefficient.
Normally the effect of temperature to VW strain gauge is little, it needn’t to be corrected. Detail
calculation method see calculation equation and related factor in calibration certificate.
4.3. Environmental Factors
Since the purpose of the Strain Gauge installation is to monitor site conditions, factors which
may affect these conditions should be observed and recorded. Seemingly minor effects may
have a real influence on the behavior of the structure being monitored and may give an early
indication of potential problems. Some of these factors include, but are not limited to: blasting,
rainfall, tidal or reservoir levels, excavation and fill levels and sequences, traffic, temperature
and barometric changes, changes in personnel, nearby construction activities, seasonal changes,
etc.