Installation & Maintenance
DVK-T DRYER BOOSTER KIT
W/SPRING WOUND TIMER
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
Страница 1: ...Installation Maintenance DVK T DRYER BOOSTER KIT W SPRING WOUND TIMER READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE ...
Страница 2: ...h all applicable codes and standards including fire rated construction c The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guidelines and safety standards as published by the National Fire Protection Association NFPA the American Society of Heating Refrigeration and Air Conditioning Engine...
Страница 3: ...ONNECT DUCT Rigid duct is recommended to optimize fan performance If using flex duct it should be stretched as smooth as possible For duct runs in unheated spaces insulated duct is recommended to reduce the effects of condensation Connect duct to the inlet and outlet ends of the fan housing by means of mounting clamps or duct tape and seal to prevent air leakage and loss of fan performance TIMER I...
Страница 4: ...ipment could result in death or serious injury 1 Fan bearings are sealed No additional lubrication is necessary 2 Periodic inspection based upon usage should be performed to ensure that the fan impeller is not obstructed The fan should be inspected a minimum of every six 6 months 3 Excessive fan noise or vibration may indicate an obstructed impeller 4 To inspect and clean impeller a Remove the duc...