Chapter XIV Waveform Generator (Option)
180
Low can be set, with the offset adjustment range of -1.25 V~1.25 V and the low level adjustment range of -2.5 V ~
1.245 V.
15.1.3 Ramp
Press down
【
WaveGen
】
key on the front panel, open the WaveGen menu, click [Waveforms] key, and open the
Waveforms menu on the right side of the screen. Click [Ramp] key, set the waveform to Ramp, and adjust the
WaveGen to corresponding menu of Ramp after selection:
Fig. 15.8 WaveGen Menu (Ramp)
Frequency/Period
Click [Frequency] or [Period] key, and the Frequency/Period menu will pop up on the right side of the screen. The
Frequency or Period can be set, with the frequency adjustment range of 100 mHz
1MHz and the period
adjustment range of 1 us ~ 10 s.
Amplitude/High
Click [Amplitude] or [High] key, and the Amplitude/High menu will pop up on the right side of the screen. The
Amplitude or High can be set, with the amplitude adjustment range of 10 mV ~ 2.5 V and the high level
adjustment range of -1.245 V ~ 2.5 V.
Offset/Low
Click [Offset] or [Low] key, and the Offset/Low menu will pop up on the right side of the screen. The Offset or
Low can be set, with the offset adjustment range of -1.25 V~1.25 V and the low level adjustment range of -2.5 V ~
1.245 V.
Symmetry
Click [Symmetry] key, and the Symmetry menu will pop up on the right side of the screen:
Fig. 15.9 Symmetry Menu
Click [Symmetry] menu key to set the ramp symmetry through the Multipurpose b or numeric keypad, with the
Symmetry adjustment range of 0% ~ 100%.
Click [Set to 0%] menu key to quickly set the ramp symmetry to 0%.
Click [Set to 50%] menu key to quickly set the ramp symmetry to 50%.
Click [Set to 100%] menu key to quickly set the ramp symmetry to 100%.
15.1.4 Pulse
Press down
【
WaveGen
】
key on the front panel, open the WaveGen menu, click [Waveforms] key, and open the
Waveforms menu on the right side of the screen. Click [Pulse] key, set the waveform to Pulse, and adjust the
WaveGen to corresponding menu of Pulse after selection:
Содержание 4456 Series
Страница 1: ...4456 Series Digital Phosphor Oscilloscope User Manual China Electronics Technology Instruments Co Ltd...
Страница 10: ...VIII...
Страница 55: ...Chapter V Trigger System 45 Fig 5 51 RF Test Signal Example...
Страница 69: ...Chapter VII Mathematical Operation 59 Fig 7 10 Advanced Math Example...
Страница 71: ...Chapter VIII Display System 61 Fig 8 3 Wfm Palette Menu Fig 8 4 Normal Palette...
Страница 72: ...Chapter VIII Display System 62 Fig 8 5 Inverted Palette Fig 8 6 Temperature Palette...
Страница 75: ...Chapter VIII Display System 65 Fig 8 12 XY Display Example...
Страница 165: ...Chapter XI Protocol Analyzer Option 155 Fig 11 242 1553 Trigger and Analysis Example...