Chapter 1 Introduction 

This chapter provides an overview of the PMC-1302 ESG and summarizes many of its key features. 

1.1 Overview 

The PMC-1302 ESG is an Industrial Ethernet Serial Gateway which provides one 10/100BaseT Ethernet 
port and two RS-485 ports. It is the ideal equipment for connecting RS-485 enabled serial devices to 
an IP-based Ethernet LAN, making it possible to access serial devices over your Ethernet network for 
any  SCADA  or  Automation  applications.  The  PMC-1302  ESG  has  been  specifically  designed  with 
industrial automation in mind and therefore provides un-surpassed performance and reliability under 
the harshest industrial or commercial environments.     

1.2 Features 

 

1x10/100BaseT, 2xRS-485 port 

 

8 kV ESD protection 

 

1.5 kV isolation protection for Ethernet port 

 

3kV isolation protection for RS-485 

 

One-key reset to default factory 

 

Simple configuration via its built-in web interface 

 

DIN-Rail Mount 

 

Extended operating temperature   

1.3 Applications 

The  PMC-1302  ESG  supports  the  efficient  transfer  of  serial  packets  between  the  upstream 
network-based  applications  and  the  downstream  RS-485  serial  devices  via  a  TCP/IP  connection. 
Instead  of  using  a  Windows  based  "Virtual  COM"  driver  with  a  port-mapping  utility,  which  is  often 
plagued with driver incompatibility among the many different Windows versions, the PMC-1302 ESG 
allows  applications  to  directly  connect  to  it  via  a  TCP/IP  connection  for  the  transparent  transfer  of 
serial  packets  inside  TCP/IP  frames  to  and  from  downstream  serial  devices.  Perfectly  suited  for 
communicating  with  industrial  devices  that  have  timing  sensitive  protocols,  the  PMC-1302  ESG 
provides  a  reliable  interface  which  allows  SCADA  or  similar  applications  that  already  support  direct 
connection  with  Ethernet  Gateway  to  communicate  with  serial  devices  independent  of  the  serial 
protocols used.   

1.4 Getting more information 

Additional information is available from CET via the following sources: 

 

Visit 

www.cet-global.com

   

 

Contact your local representative 

 

Contact CET directly via email a

[email protected]

 

 

Содержание PMC-1302

Страница 1: ...PMC 1302 Ethernet Serial Gateway User Manual Version V1 1 February 28 2020...

Страница 2: ...m CET Electric Technology CET The information contained in this Manual is believed to be accurate at the time of publication however CET assumes no responsibility for any errors which may appear here...

Страница 3: ...ot accept liability for any damage caused by device malfunctions CET accepts no responsibility for the suitability of the device to the application for which it was purchased Failure to install set up...

Страница 4: ...8 3 1 Front Panel LED Indicators 8 3 2 Reset Button 8 3 3 Typical Application 8 Chapter 4 Configuring the PMC 1302 ESG via Web Interface 9 4 1 Web Console Login 9 4 2 Ethernet 10 4 3 Serial Port 10 4...

Страница 5: ...nt Extended operating temperature 1 3 Applications The PMC 1302 ESG supports the efficient transfer of serial packets between the upstream network based applications and the downstream RS 485 serial d...

Страница 6: ...llation make sure that the DIN rail is already in place Move the installation clip at the back of the PMC 1302 downward to the unlock position Align the top of the mounting channel at the back of the...

Страница 7: ...485 communications connections on the PMC 1302 ESG Figure 2 5 RS485 Communications Connections 2 4 Ethernet Port 10 100BaseT The PMC 1302 ESG comes standard with an Ethernet Port P1 using the MDI MID...

Страница 8: ...g data P3 Green Blinking P3 is receiving data Yellow Blinking P3 is transmitting data Table 3 1 LED Indicators 3 2 Reset Button There is a Reset button at the lower right hand corner of the PMC 1302 s...

Страница 9: ...he window The Security Settings window appears Enable the three options as shown below and then click OK Figure 4 1 Internet Setting 2 The default IP Address of the PMC 1302 ESG s Ethernet Port is 192...

Страница 10: ...ream RS485 devices Please be reminded that the IP Port number of the Serial Gateway feature for P2 default 20000 and P3 default 20001 should be different Click Save to confirm your changes The followi...

Страница 11: ...ient The following parameters only appear when the Mode is set to TCP Client Please note that the TCP Client function is reserved for future applications Master IP Port 1 to 60000 20001 Master IP Addr...

Страница 12: ...it when the dialog box appears Figure 4 9 Quit from Device Information Screen 4 7 Reboot Configuration changes will not take effect until the Reboot operation has been executed Click Reboot on the lef...

Страница 13: ...ser can log on to its Web Console page via the Internet Explorer by entering the IP address of the PMC 1302 ESG s Ethernet port in the browser s address bar For example type http 192 168 0 127 at the...

Страница 14: ...k Reboot on the left hand pane and then click the Reboot button on the right hand pane to save the settings The PMC 1302 ESG will perform a reboot operation with the new configuration When the Log In...

Страница 15: ...al 3 Port Type Ethernet 4 IP 192 168 0 127 5 Port 20001 for P2 of PMC 1302ESG Figure 5 6 Site Node Properties Select PMC 660 on the right hand pane under the Device Name column and then click the Prop...

Страница 16: ...ile and select the appropriate SNF file from the pop up dialog box Figure 5 7 Import SNF File Click the Save icon on the Tool Bar to save the current configuration into PecStar iEMS s database The Pec...

Страница 17: ...n Blinking Receiving activity P2 P3 Yellow Blinking Transmitting activity Protocol Protocol TCP UDP HTTP Power Supply L N Standard Burden 95 250VAC DC 47 440Hz 3W Protection ESD Protection Isolation P...

Страница 18: ...08 Level III Radiated Fields IEC 61000 4 3 2008 Level III Fast Transients IEC 61000 4 4 2004 Level III Surges IEC 61000 4 5 2005 Level III Conducted Disturbances IEC 61000 4 6 2008 Level IV Magnetic F...

Страница 19: ...19 CET Electric Technology Appendix C Ordering Guide...

Страница 20: ...lectric Technology Contact us A CET Electric Technology Inc 8 F Westside Building 201 Terra Industrial Tradepark Che Gong Miao Shenzhen Guangdong P R China 518040 E support cet global com W www cet gl...

Отзывы: