background image

 

 C.E.T. Fire Pumps Mfg. This handbook is subject to change without notice, 

Contact your local C.E.T. dealer or C.E.T. direct to ensure you have the latest version.

 

 

 

 
 

Instruction Handbook  

 

(Version 1.0) 

 

Model: PFP-2hpHND-M 

 

 

 

 

Your version of the pump, the engine and their accessories may vary from the one seen on the illustrations

Serial Number : ________________________________ 

 

This pump was built by :  

C.E.T. Fire Pumps Mfg.  

Содержание PFP-2hpHND-M

Страница 1: ...or C E T direct to ensure you have the latest version Instruction Handbook Version 1 0 Model PFP 2hpHND M Your version of the pump the engine and their accessories may vary from the one seen on the il...

Страница 2: ...C E T direct to ensure you have the latest version Table of contents 1 FOREWORD 3 2 SAFETY INSTRUCTIONS 4 3 DESCRIPTION 7 4 GENERAL INSTRUCTIONS 10 5 TRANSPORT AND STORAGE 11 6 PERFORMANCE 12 7 STARTI...

Страница 3: ...of experience in building fire fighting equipment If you follow the directives given in this handbook your pump will be a useful ally for many years to come For your own safety and those around you i...

Страница 4: ...er o NEVER run the engine without a muffler or proper exhaust system o NEVER operate the engine if the fuel tank cap is removed do not fill the tank while the engine is running If fuel is spilled move...

Страница 5: ...ot water scald and burn hazards NEVER let the pump run for more than one minute with discharge valve s completely closed When the pump is running make sure to always leave the discharge valve slightly...

Страница 6: ...attached note will put at risk the security of the personnel operating near the pump The words danger warning and caution are used for levels of risk This symbol means that it is mandatory to read and...

Страница 7: ...nsure you have the latest version 3 Description This portable pump is directly driven by the very high quality Honda gasoline 2 5 hp engine It is equipped with a backup recoil starter It has an integr...

Страница 8: ...esistance aluminum alloy body It also has an axial mechanical seal The pump can operate to a maximum pressure of 50 PSI 3 4bar It has been designed to work at a temperature between 5 F 15 C and 104 F...

Страница 9: ...operly ventilated area Recommended individual protective equipments not included Firefighting grade protective gloves conforms to EN659 or equivalent Protective glasses Hearing protection Intended use...

Страница 10: ...e end of the suction hose If you are not sure of the quality of the pumped water use a floating strainer to prevent drawing the sand or stone from bottom source The Honda GXH50 engine runs on unleaded...

Страница 11: ...an 35 during transport especially if the engine has oil in it Storage Warning It is important to take into account the dangerous materials and components such as diesel oil and the battery Store away...

Страница 12: ...ces Normal conditions geostatic height of 4 10 1 5m temperature de 59 F 15 C water clear of sand and debris atmospheric pressure 3280 1000m from sea level None conformance to the instructions given in...

Страница 13: ...ve the latest version 7 Starting procedure 7 1 Place the pump on a flat and stable surface with an angle less than 15 Place your pump as close as possible to the water source WARNING NEVER run the eng...

Страница 14: ...the safety of your installation Warn the surrounding people before you start the pump It is important that you evaluate the trajectory of the hose to prevent incidents NOTE If you are pumping from a...

Страница 15: ...d priming handle CAUTION NEVER run the pump dry for more than one 1 minute it could damage the mechanical seal Always prime the pump as fast as possible 7 11 When water comes out of the hand primer it...

Страница 16: ...to change without notice Contact your local C E T dealer or C E T direct to ensure you have the latest version WARNING NEVER run the pump at high speed with the discharge valve closed more than one 1...

Страница 17: ...leave water inside the casing of the pump and valves The water could freeze and damage them CAUTION After each use it is important to flush the inside of your pump with fresh water This will help prev...

Страница 18: ...est Functional test Connect suction hose of 1 5 diameter and a length of 10 Make sure to completely submerge the end of the suction hose at least 12 Connect a discharge hose of 1 5 diameter and not mo...

Страница 19: ...Dispose properly of the used oil and filters according to the local environmental regulations WARNING Never run the pump if the inlet strainer is not on or is damaged Maintenance Interval Daily First...

Страница 20: ...ight Make sure to have well understood and applied the priming protocol of the pump Check for any possible air leakage in the suction hose Check the mechanical seal for leakage Faulty engine Refer to...

Страница 21: ...osits or dust is obstructing the priming system Carefully dismantle the priming system clean it up or replace the components if necessary The engine runs fine but the pump output is low The restrictio...

Страница 22: ...PUMPS MFG incurs no liability under this warranty or otherwise for equipment which has been abused altered or improperly maintained or for equipment which has been returned for inspection or repair m...

Страница 23: ...T direct to ensure you have the latest version 13 Contact Us For repair or questions about warranties please contact your local C E T fire pumps dealer E mail service fire pump com Tel 1 450 568 2719...