background image

*

C

E

T

 i

a

 t

ra

d

e

m

a

rk

 o

C

E

T

 F

ir

e

 P

u

m

p

M

fg

 L

td

.

75 Hector St., P.O. Box 90, Pierreville (Québec) Canada  J0G 1J0      Telephone: 1-800-567-2719      Fax: 1-800-434-2613      

www.fire-pump.com

ACCEPT ONLY THE BEST

A   C E N T U R Y   O F   E N G I N E E R I N G   F O R   T H E   B R A V E S T

PFP-11hpHND-M-HP

INSTRUCTIONS  MANUAL

Congratulation, you have just purchased a C.E.T. portable pump.  If you follow the procedures in this
operation manual, it will give you years of use without any problems.

ENGINE SPECIFICATIONS

• Honda 11hp at 3600 RPM, air cooled engine.
• Single cylinder gasoline engine.
• Manual recoil start.
• 6 quarts (6.5 l) integrated fuel tank.

PUMP UNIT SPECIFICATIONS

• Transmission drive C.E.T. single stage centrifugal pump.
• Pump body made from resistant aluminum alloy.
• Bronze impeller.
• Mechanical shaft seal.
• Stainless steel pump shaft
• Exhaust priming system, guaranteed up to 15’ (4.5 meter) lift.
• One 1 1/2” (38 mm) delivery outlet with 1/4-turn ball valve.
• One 2 1/2 ” (65 mm) suction inlet.
• Dimensions : Length : 24” (609 mm); Width : 26 3/4 ” (679 mm); Height : 23 7/8” (606 mm).
• Weight : 150 lbs (68 kg).

INCLUDED ACCESSORIES

• Pressure gauge.
• Low oil alert.

PERFORMANCE

72 GPM (272 LPM)  @  50   PSI   (3.5 bar)
65 GPM (246 LPM)  @  100 PSI   (6.9 bar)
42 GPM (159 LPM)  @  150 PSI (10.3 bar)
15 GPM   (57 LPM) @  175 PSI (12.1 bar)
5 GPM   (19 LPM)  @  200 PSI (13.8 bar)

Your pump comes with a full year warranty on all mechanical components.

Содержание PFP-11hpHND-M-HP

Страница 1: ...al recoil start 6 quarts 6 5 l integrated fuel tank PUMP UNIT SPECIFICATIONS Transmission drive C E T single stage centrifugal pump Pump body made from resistant aluminum alloy Bronze impeller Mechanical shaft seal Stainless steel pump shaft Exhaust priming system guaranteed up to 15 4 5 meter lift One 1 1 2 38 mm delivery outlet with 1 4 turn ball valve One 2 1 2 65 mm suction inlet Dimensions Le...

Страница 2: ...ter below the inlet of the suction hose Allow your pump to run without surveillance Run the pump with the discharge valve closed for more than 1 minute STARTING PROCEDURE Place your pump on a hard stable surface within 15 from horizontal Check the oil Check the gas tank level Connect your suction hose Make sure that there is a rubber seal on the adapter and screw it tight Close all the drain valve...

Страница 3: ...pump will help prevent the pump from seizing up TROUBLESHOOTING Before calling us try the following if your pump does not operate properly If the venturi does not work properly Check the exhaust port it should be closed tightly without any exhaust gas whistling out between the seal and the pipe Check the casing drain valve it should be closed Check any air leakage from suction hose If the engine s...

Страница 4: ... or improperly maintained or for equipment which has been returned for inspection or repair more than ten 10 days after defect complained of has been or should have been discovered by the Purchaser or Equipment which is operated after the defect has been discovered 3 CET incurs no liability for alteration or repairs unless the Purchaser first receives CET written consent or approval CET will not b...