CET Electric Technology
112
64
Return Value
Over kW Total Predicted Setpoint Return
65
Return Value
Over kvar Total Predicted Setpoint Return
66
Return Value (x1000)
Over PF Total Predicted Setpoint Return
67
Return Value (x100)
Over Voltage THD Setpoint Return
68
Return Value (x100)
Over Voltage TOHD Setpoint Return
69
Return Value (x100)
Over Voltage TEHD Setpoint Return
70
Return Value (x100)
Over Current THD Setpoint Return
71
Return Value (x100)
Over Current TOHD Setpoint Return
72
Return Value (x100)
Over Current TEHD Setpoint Return
73
Return Value (x10)
Over Voltage Unbalance Setpoint Return
74
Return Value (x10)
Over Current Unbalance Setpoint Return
75
Return Value (x100)
Over Voltage OverDeviation Setpoint Return
76
0
Over Voltage Phase Reversal Setpoint Return
77
Return Value (x1000)
Over Ir Setpoint Return
78
Return Value (x100)
Over U2 (Negative Sequence Voltage) Setpoint Return
79
Return Value (x100)
Over U0 (Zero Sequence Voltage) Setpoint Return
80
0
Over Current Phase Reversal Setpoint Return
81~90
-
Reserved
91
Trigger Value (x100)
Under Uln Setpoint Active
92
Trigger Value (x100)
Under Ull Setpoint Active
93
Trigger Value (x1000)
Under Current Setpoint Active
94
Trigger Value (x1000)
Under I4 Setpoint Active
95
Trigger Value (x100)
Under Freq. Deviation Setpoint Active
96
Trigger Value
Under kW Total Setpoint Active
97
Trigger Value
Under kvar Total Setpoint Active
98
Trigger Value (x1000)
Under PF Total Setpoint Active
99
0
DI1 Open Setpoint Active
100
0
DI2 Open Setpoint Active
101
0
DI3 Open Setpoint Active
102
0
DI4 Open Setpoint Active
103
0
DI5 Open Setpoint Active
104
0
DI6 Open Setpoint Active
105
Trigger Value
Under AI Setpoint Active
106
Trigger Value
Under kW Total Demand Setpoint Active
107
Trigger Value
Under kvar Total Demand Setpoint Active
108
Trigger Value (x1000)
Under PF Total Demand Setpoint Active
109
Trigger Value
Under kW Total Predicted Setpoint Active
110
Trigger Value
Under kvar Total Predicted Setpoint Active
111
Trigger Value (x1000)
Under PF Total Predicted Setpoint Active
112
Trigger Value (x100)
Under Voltage THD Setpoint Active
113
Trigger Value (x100)
Under Voltage TOHD Setpoint Active
114
Trigger Value (x100)
Under Voltage TEHD Setpoint Active
115
Trigger Value (x100)
Under Current THD Setpoint Active
116
Trigger Value (x100)
Under Current TOHD Setpoint Active
117
Trigger Value (x100)
Under Current TEHD Setpoint Active
118
Trigger Value (x10)
Under U2 Unbalance Setpoint Active
119
Trigger Value (x10)
Under I2 Unbalance Setpoint Active
120
Trigger Value (x100)
Under Voltage OverDeviation Setpoint Active
121
-
Reserved
122
Trigger Value (x1000)
Under Ir Setpoint Active
123
Trigger Value (x100)
Under U2 (Negative Sequence Voltage) Setpoint Active
124
Trigger Value (x100)
Under U0 (Zero Sequence Voltage) Setpoint Active
125~135
-
Reserved
136
Return Value (x100)
Under Uln Setpoint Return
137
Return Value (x100)
Under Ull Setpoint Return
138
Return Value (x1000)
Under Current Setpoint Return
139
Return Value (x1000)
Under I4 Setpoint Return
140
Return Value (x100)
Under Freq. Deviation Setpoint Return
141
Return Value
Under kW Total Setpoint Return
142
Return Value
Under kvar Total Setpoint Return
143
Return Value (x1000)
Under PF Total Setpoint Return
144
1
DI1 Open Setpoint Return
145
1
DI2 Open Setpoint Return
146
1
DI3 Open Setpoint Return
147
1
DI4 Open Setpoint Return
148
1
DI5 Open Setpoint Return
149
1
DI6 Open Setpoint Return
150
Return Value
Under AI Setpoint Return
151
Return Value
Under kW Total Demand Setpoint Return
152
Return Value
Under kvar Total Demand Setpoint Return
153
Return Value (x1000)
Under PF Total Demand Setpoint Return
154
Return Value
Under kW Total Predicted Setpoint Return
155
Return Value
Under kvar Total Predicted Setpoint Return
156
Return Value (x1000)
Under PF Total Predicted Setpoint Return
157
Return Value (x100)
Under Voltage THD Setpoint Return
158
Return Value (x100)
Under Voltage TOHD Setpoint Return
159
Return Value (x100)
Under Voltage TEHD Setpoint Return
160
Return Value (x100)
Under Current THD Setpoint Return
161
Return Value (x100)
Under Current TOHD Setpoint Return
162
Return Value (x100)
Under Current TEHD Setpoint Return
163
Return Value (x10)
Under U2 Unbalance Setpoint Return
164
Return Value (x10)
Under I2 Unbalance Setpoint Return