5.1 Details on opening doors
Procedure:
Steps
Signal
1. Hold an authorised locking medium in the reading field of the locking device for
approx. 1 second (maximum distance approx. 10 mm).
Locking medium is read and accepted.
1x
short green
The electronic furniture lock is released.
Troubleshooting:
Signal
Cause
Solution
The locking medium
cannot be read (no
signal).
The locking medium was not held close enough to
the reading field of the locking device.
Hold the locking medium closer to the reading
field of the locking device.
The reading field of the locking device was covered
by metallic materials.
Remove the metallic materials from the
reading field of the locking device.
Another authorised locking medium was recently
held in the reading field of the locking device and
the opening duration of the locking device has not
yet expired.
You can open the door without your locking
medium being read.
The battery is flat.
Replace the batteries.
The locking medium is defective.
Contact the OMEGA FLEX system administrator.
4x
short red
The locking medium is not authorised.
Contact the OMEGA FLEX system administrator.
The locking medium is authorised but the blocking
time or block mode is active.
A locking device cannot be opened by an
authorised locking medium if the blocking time
or block mode is active.
1x
long green
The locking medium is authorised and the locking
device is currently in release mode.
You can also open the door even without an
authorised locking medium.
RFID furniture lock