background image

 

     Introduction 

OMEGA FLEX  
RF-NET Access Point 

 

Page 17 of 34 

 

5.7

 

RF ranges 

 

Ensure that the permissible RF ranges are observed.  Install 

the devices within the maximum RF range of 25 metres. 

 

5.7.1

 

Checking the range  

  

The optional RF-TRACE-MASTER transponder card allows you to 
check the quality of the radio frequency (RF) link between the 

OMEGA server and your locking devices. 
The RF-TRACE-MASTER triggers the following signals of your 

locking devices: 

 

Hold the RF-TRACE-MASTER for about two seconds in front 

of your locking cylinder or wall terminal. 

 

Содержание Omega Flex RF-NET

Страница 1: ...OMEGA FLEX RF NET Access Point Fitting and Operating Instructions Translated fitting and operating instructions version 1 2 11 2014...

Страница 2: ...larations of Conformity 8 4 4 Basic safety instructions 9 5 Introduction 11 5 1 Description 11 5 2 Components of a wireless system 13 5 3 OMEGA system components 14 5 4 Scope of delivery 15 5 5 Unpack...

Страница 3: ...nts are highlighted with defined layout features Additional information on the efficient use of the Access Point Reference to additional information The electronic components of the Access Point may b...

Страница 4: ...reach at all times as long as the Access Point is used These Fitting and Operating Instructions should be handed over to the end users Be sure to use the most recent version of these Fitting and Oper...

Страница 5: ...has not yet taken place please contact your professional CEStronics partner to obtain training on the product NOTICE Unintended condition of your system possible If you are not fully familiar with th...

Страница 6: ...1 Explanation of the safety notes These Fitting and Operating Instructions include safety notes of the following types NOTICE These notes warn against possible property or environmental damage CAUTION...

Страница 7: ...are transmitted via 868 MHz radio signals The connection of the Access Point to the master computer is wired The OMEGA FLEX Access Point must not be changed without our written consent It is exclusive...

Страница 8: ...For your safety OMEGA FLEX RF NET Access Point Page 8 of 34 4 3 CE Declarations of Conformity...

Страница 9: ...packaging material and or plastic bags There is a risk that children pull them over their head and suffocate 4 4 3 Danger of poisoning Always keep the Access Point out of the reach of children There...

Страница 10: ...does not exceed 95 Do not use the Access Point in rooms with a high level of dust formation Do not use the Access Point near sources of heat Do not expose the Access Point to temperatures below 0 C or...

Страница 11: ...rk interface of the system The desired access authorizations are created in the control centre and transmitted via the Ethernet to the Access Points The Access Points then transmit the authorizations...

Страница 12: ...ption makes it possible to transmit the network signal via the 230 V power network using suitable adapters This means that no separate network cables must be installed PoE Power over Ethernet adapter...

Страница 13: ...ows Server 2008 or Windows Server 2013 Network card TCP IP Monitor with a resolution of 1024 768 pixel or higher OMEGA Access Points pos 3 maximum ten points of entry per Access Point additional Repea...

Страница 14: ...g media optional Your locking devices can be operated with the following locking media Transponder key key fob card 2 Locking devices optional 3 Access Point 4 RF NET Repeater to extend the range of A...

Страница 15: ...ase check the contents of the package and the scope of delivery Check new devices for transport damage and inform your CEStronics partner promptly if any damage is found 5 4 1 Device overview 1 Access...

Страница 16: ...uch as film padding and packaging board NOTICE Risk of damage to the Access Point Only use the supplied power pack for the power supply of your Access Point 5 6 Connections 1 Socket for the plug in po...

Страница 17: ...of 25 metres 5 7 1 Checking the range The optional RF TRACE MASTER transponder card allows you to check the quality of the radio frequency RF link between the OMEGA server and your locking devices Th...

Страница 18: ...RF link Green LED of your locking cylinder IES fitting or wall terminal flashes once adequate RF link If the red LED of your locking device flashes the RF link is not OK and must be checked If the red...

Страница 19: ...e separated at any time NOTICE The Access Point may be damaged if not fitted properly Only skilled personnel may fit the Access Point This personnel must have been trained on the product by CEStronics...

Страница 20: ...ence with the radio traffic The Access Point may not be fitted outdoors The Access Point is supplied preassembled To commission your Access Point you only have to fasten the wall mount at a suitable p...

Страница 21: ...s possible If the reception is good install the Access Point with the ports pointing downwards However also all other orientations are possible such as with the antenna pointing to the as shown in the...

Страница 22: ...yet been screwed in tight it can be rotated by 360 After it has been tightened the antenna can only be aligned vertically and horizontally If the RF link is satisfactory fit the Access Point permanent...

Страница 23: ...properly after it has snapped in the wall mount Do not yet screw the antenna 1 tight in the antenna base 2 at this point Do not use any tools for tightening Establish the required cable connections as...

Страница 24: ...iated power As long as the antenna has not yet been screwed in tight you can rotate it by 360 and align it vertically and horizontally Once you have found the best position of the antenna tighten it w...

Страница 25: ...l the following conditions Signal Meaning Green LED permanent Network connection established perfect connection to the OMEGA server Red LED flashing Operative Red LED flashes short flickers Data trans...

Страница 26: ...to surfaces of the Access Point Never use solvent containing cleaning agents to avoid damage to your devices 8 Maintenance Have the Access Point serviced and its perfect functioning verified every si...

Страница 27: ...res or faulty connections Check the continuity of your wires with a suitable instrument multimeter ohmmeter Verify the proper functioning of the plug in power supply of the Access Point with a suitabl...

Страница 28: ...Reduce the distance to your locking devices Verify the quality of the wireless transmission with the optional RF TRACE Master The locking devices have no power Check the power supply of your locking d...

Страница 29: ...ed in the OMEGA User Manual Check the functioning of the software as described in the OMEGA User Manual Verify the perfect functioning of your PC If you are not able to verify the perfect functioning...

Страница 30: ...xternal packaging and inserts made of cardboard inserts and protective film made of polypropylene PE Please dispose of the packaging in an environmentally responsible manner through separate waste str...

Страница 31: ...pack supplied Power consumption Max 1 0 W Connection Phonoplug 5 5 2 1 mm 5 5 mm 2 1 mm Communication frequency Sending transmitting 868 MHz Network protocol TCP IP RF range approx 25 m Temperature ra...

Страница 32: ...f Master media the SYSTEM MASTER and the PROGRAM MASTER Optional transponder cards also have Master medium status Locking medium A medium with which you can lock and unlock an electronic locking cylin...

Страница 33: ...nce damage as a consequence of improper installation damage as a consequence of improper maintenance damage as a consequence of improper operation damage as a consequence of excess voltage damage as a...

Страница 34: ...1 204 229 info ces locks de CESitalia srl V d vecchie Fondamenta 4 Stra e d A Gr ndungen 4 I 39044 Egna Neumarkt BZ 39 0471 812 294 39 0471 812 294 info it ces eu www ces eu it CESrom srl Str Metalurg...

Отзывы: