background image

AccessOne

Door controllers

Door controller TSG1/SDC

Assembly and operating manual

English

Version

VA1

BRO2321

www.ces.eu

Subject

to

change

without

notice.

BRO2321VA1

Содержание AccessOne TSG1/SDC

Страница 1: ...AccessOne Door controllers Door controller TSG1 SDC Assembly and operating manual English Version VA1 BRO2321 www ces eu Subject to change without notice BRO2321VA1...

Страница 2: ...3 1 Scope of delivery 8 3 2 Parts designations 8 4 Assembly 10 4 1 Mounting preparation 10 4 2 Assembly 11 4 3 Disassembly 13 5 Connections and wiring 16 5 1 Tamper RS232 power 16 6 Technical data 20...

Страница 3: ...C Ed Schulte GmbH Zylinderschlossfabrik Velbert Germany BRO2321 2 Version VA1 Always use the most up to date version of this manual You can obtain updated versions free of charge from www ces eu Notes...

Страница 4: ...rofessional experience and or relevant training in electronics For some tasks it may be necessary for specialists to have received training on the product beforehand Particular characteristics of the...

Страница 5: ...olling doors in an AccessOne access control system The product is intended solely for and may only be used for this purpose Any other use is deemed to be improper use and could result in property dama...

Страница 6: ...se an explosion and cause injury to persons Do not use the device in potentially explosive areas 2 3 3 Danger of material damage Hard shocks Hard shocks can damage mechanical and electronic components...

Страница 7: ...t all Have the device maintained and checked for proper functioning every six months by CES or a CEStronics partner Always have repairs performed by qualified personnel Use only accessories and spare...

Страница 8: ...only one output is required per door in order to open it two doors can be controlled in the same direction with one reader each 3 1 Scope of delivery 1 Door controller housing 2 Fixing screws upper pa...

Страница 9: ...3 2 2 Circuit board 1 Connection terminals 2 Jumpers 3 Reset button 4 RJ45 connector 5 SD card slot www ces eu Subject to change without notice BRO2321VA1...

Страница 10: ...ixing screws PZ2 Cross head screwdriver Fixing screws Slotted screwdriver Cover strip removal Use appropriate fixing material You can obtain WALL PLUGS and FIXING SCREWS from your partner for fixing t...

Страница 11: ...delivery 2 Feed the wiring from below Ensure that there is sufficient strain relief e g with a a cable tie 3 Wire the connections according to the respective terminal assignment see installation inst...

Страница 12: ...4 Fasten the upper part of the housing with screws included in the scope of delivery 5 Secure the front cover strips www ces eu Subject to change without notice BRO2321VA1...

Страница 13: ...The door control is mounted 4 3 Disassembly 1 Carefully lever out the front cover strips with a suitable tool www ces eu Subject to change without notice BRO2321VA1...

Страница 14: ...2 Remove the front cover strips 3 Remove the fastening screws of the upper part of the housing www ces eu Subject to change without notice BRO2321VA1...

Страница 15: ...4 Remove the upper part of the housing The housing is open www ces eu Subject to change without notice BRO2321VA1...

Страница 16: ...ional contacts e g tamper and connecting the power supply 5 1 1 Tamper No Connection 1 Tamper 2 Tamper 5 1 2 RS232 No Connection Function 1 RX Receive Data cable for outgoing data negative logic 2 TX...

Страница 17: ...oltages are measured against this cable 3 RS485 A Wiegand D1 4 RS485 B Wiegand D0 5 LED green Ground Signal voltages are measured against this cable 6 LED red Ground Signal voltages are measured again...

Страница 18: ...the jumper settings to suit the interface configuration active passive Passive No Connection Function 1 5 24 V DC Power supply 2 GND Ground Signal voltages are measured against this cable Active No C...

Страница 19: ...eferably that can be supplied constantly by free wheeling diode OUT potential free No Connection 1 Normally open contact NO 2 Changeover Com 3 Normally closed contact NC OUT active No Connection Funct...

Страница 20: ...A 20 active Operating output readers 1 and 2 at 12 V 2 0 A 20 Communication UDP port 10001 Prohibited atmospheres Not suitable for use in corrosive atmospheres chlorine ammonia lime water Protection c...

Страница 21: ...r a CEStronics partner 7 2 Care for your devices You can clean the external accessible parts of your devices housing labelling etc with a soft slightly damp cloth Do not use oils or lubricants to main...

Страница 22: ...hold waste Electronic equipment contains a wide variety of substances and materials If waste electrical and electronic equipment WEEE is not disposed of correctly environmental and health risks may ar...

Страница 23: ...C Ed Schulte GmbH Zylinderschlossfabrik Friedrichstra e 243 D 42551 Velbert 49 2051 204 0 49 2051 204 229 info ces eu www ces eu...

Отзывы: