Cermetek Microelectronics, Inc Page 30 of 42
Document NO. 607-00xx Revision A (12/13)
4.2.5.7
AT+UARTFL
: This command allows the user to Read or control the auto frame trigger length.
Read Auto-Frame Trigger length
AT+UARTFL<CR>
+ok=<len><CR>< LF ><CR>< LF >
Set Auto-Frame Trigger Timer
AT+ UARTF=<len ><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
len = Auto-Frame Trigger length in bytes; Range 64 to 4096;
4.2.5.8
AT+TMODE
: this command allows the user to Set or Read the data transmission mode.
Read Data Transmission Mode
AT+TMODE<CR>
+ok=<tmode><CR>< LF ><CR>< LF >
Set Data Transmission Mode
AT+ TMODE=<tmode ><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
tmode = through; Transparent transmission selected;
= Agreement; Agreement transmission selected
Note:
New settings for AT+TMODE do not become active until the CH232BGN module reboots.
4.2.5.9
AT+WMODE
: This command allows the user to read or set the WiFi Mode.
Read WiFi Mode
AT+WMODE<CR>
+ok=<mode><CR>< LF ><CR>< LF >
Set WiFi Mode
AT+WMODE=<mode ><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
mode = AP; module set as Access Point;
= STA; module set as Station
Note:
New settings for AT+WMODE do not become active until the CH232BGN module reboots.