6.3
Installing the Diplexer on the Radio
The IP-20C-HP is delivered as two separate components: a generic radio unit and a
diplexer unit. This section explains how to attach the diplexer unit to the radio
unit.
Note:
Mounting of the diplexer unit to the radio unit should be performed by
certified personnel in a clean, temperature and humidity-controlled
environment.
List of Items
Item
Description
Quantity Marketing Model
1
IP-20C-HP Radio Unit
1
See Section 2.4.1,
2
IP-20C-HP Diplexer Unit
1
See Section 2.4.2,
Required Tools
•
Torque Wrench With Metric Hexagon Socket Key Wrench #4 (Allen Key)
Procedure
1 Prior to the installation, remove the sticker which is covering the diplexer
ports on the Diplexer unit and the sticker that covers the TRX ports on the
radio unit.
2 Position the diplexer unit on the radio unit so that the two location pins
mounted on the TRX ports of the diplexer unit (
) fit into the
corresponding holes in the radio unit (