Installation Guide for FibeAir IP-20C-HP
Page 34 of 204
Ceragon Proprietary and Confidential
Caution!
The user power supply GND must be connected to the positive
pole in the IP-20C-HP power supply.
Any other connection may cause damage to the system!
Note!
For the warranty to be honored, you must install the IP-20C-HP
in accordance with the instructions above.
4.4
Surge Protection
IP-20C-HP includes built-in surge protection for its Ethernet and power interfaces.
IP-20C-HP
’s surge protection implementation complies with
the standards set
forth in the
Surge Protection
Requirements section of the IP-20C-HP Technical
Description, provided the Ethernet cables were prepared according to the
instructions in
on page 54.
In areas in which severe lighting conditions are likely to occur, it is strongly
recommended to add additional protection by placing lightning protectors on all
electrical Ethernet cables, near the connection points with the IP-20C-HP unit.
4.5
Available Cable Options
4.5.1
Fiber Optic Cables - Single Mode
Table 13: Fiber Optic Cables - Single Mode
Marketing Model
Description
IP-20_FO_SM_LC2LC_ARM_7m
CABLE,FO,DUAL LC/LC,7M,SM,55mm OPEN END,M28
GLAND,ARMORED,OU
IP-20_FO_SM_LC2LC_ARM_15m
CABLE,FO,DUAL LC/LC,15M,SM,55mm OPEN END,M28
GLAND,ARMORED,O
IP-20_FO_SM_LC2LC_ARM_30m
CABLE,FO,DUAL LC/LC,30M,SM,55mm OPEN END,M28
GLAND,ARMORED,O
IP-20_FO_SM_LC2LC_ARM_50m
CABLE,FO,DUAL LC/LC,50M,SM,55mm OPEN END,M28
GLAND,ARMORED,O
IP-20_FO_SM_LC2LC_ARM_70m
CABLE,FO,DUAL LC/LC,70M,SM,55mm OPEN END,M28
GLAND,ARMORED,O
IP-20_FO_SM_LC2LC_ARM_80m
CABLE,FO,DUAL LC/LC,80M,SM,55mm OPEN END,M28
GLAND,ARMORED,O
IP-20_FO_SM_LC2LC_ARM_100m
CABLE,FO,DUAL LC/LC,100M,SM,55mm OPEN END,M28
GLAND,ARMORED
IP-20_FO_SM_LC2LC_ARM_150m
CABLE,FO,DUAL LC/LC,150M,SM,55mm OPEN END,M28
GLAND,ARMORED