Installation Guide for FibeAir IP-20C-HP
Page 31 of 204
Ceragon Proprietary and Confidential
4.
Cable Installation and Grounding
4.1
Minimum and Maximum Cable Diameter
To fit the gland, the outer cable diameter should be between 6-10 mm. This
applies to all glands on the IP-20C-HP unit.
4.2
Grounding the Cables
Cables must be grounded as follows:
•
Connecting an Optical Fiber Cable and SFP
on page 47), no grounding is
required.
•
For DC power cables (see
on page 51), no grounding is
required.
•
For Ethernet cables, the shielded Ethernet cable (SF/UTP construction) should be grounded
to the antenna tower at the top (next to the IP-20 unit), the entry to the indoor cabinet, and
every 50m, using the kit CAT6a_gnd_kit.
Figure 18: Cable Grounding
Table 12: Cable Grounding Kit
Marketing Model
Description
CAT6a_gnd_kit
Universal Grounding Kit