FibeAir® IP-10C
Installation Guide
Ceragon Proprietary and Confidential
Page 42 of 63
3.4
1+1 HSB Remote Mount Installation
The following components are necessary for a 1+1 HSB remote mount
installation:
Item
Description
Quantity Remarks
I
IP-10C RADIO
2
2
RFU-C COUPLER KIT
1
3
RFU-C REMOTE MOUNT ADAPTOR KIT
1
For 6-13 GHz
In 1+1 remote mount configuration, the IP-10C is attached to a coupler.
Important!
Do not remove the transparent pressure window located on
the coupler ports!
To install an IP-10C in a 1+1 HSB remote mount configuration:
1 For 6-13 GHz installations only, mount the RFU-C remote adaptor and
O-Ring to the pole mount using the four flat M5 screws supplied in the
RFU-C Remote Mount Adaptor kit, and tighten the screws.
2 Mount the IP-10C coupler to the RFU-C pole mount bracket using the four
M8 screws and washers supplied with the RFU-C Coupler kit, and tighten
the screws.