FibeAir® IP-10C
Installation Guide
Ceragon Proprietary and Confidential
Page 18 of 63
2.9.1
Connecting the Waveguide in 6-13 GHz Bands
1 Mount the remote adaptor and O-Ring to the pole mount using the four M5
flat screws supplied in the Remote Mount Adaptor kit, and tighten the
screws.
2 Connect the flexible waveguide to the remote mount adaptor. Use screws
(supplied with the waveguide kit) to fasten the waveguide.
2.9.2
Connecting the Waveguide in 15-42 GHz Bands
1 Remove the iris from the IP-10C (no adaptor is required for the 15-42 GHz
bands).
2 Connect the waveguide to the antenna adaptor interface (the interface
exposed by removing the iris). Use four screws (supplied with the
waveguide kit) to fasten the waveguide end to the antenna adapter
interface.