Century VGreen Скачать руководство пользователя страница 1

1

PART

PART 

NUMBER

QTY

IMAGE

Terminal Box 

Cover Assembly

2513409-001 

(Grey)

2513409-002 

(Black)

1

Plug

2514059-001

4

Screw Driver

2517831-001

1

PART

PART 

NUMBER

QTY

IMAGE

Autolmation

Adapter

2517369-001 

1

Digital Input 

Cable

2517463-001

4

Lead Cable

2517465-001 25 FT

RS-485 

Connector

2511130-001

1

Conduit Fitting

2017587-002

1

TABLE OF CONTENTS
1.0   KIT CONTENTS ....................................................................................................... 1
2.0   INTRODUCTION ...................................................................................................... 2
3.0   OVERVIEW .............................................................................................................. 2
4.0  CONNECTING TO A VGREEN  MOTOR ................................................................... 2
5.0  CONNECTING TO AN ALTERNATE POWER SOURCE ........................................... 5
6.0  CONNECTING TO AN AUTOMATION SYSTEM ..................................................... 5

6.1  Using automation system output connectors .................................................. 5
6.2  Using automation system relays ........................................................................ 5

6.2.1  Connecting to input side of relays ............................................................... 5
6.2.2  Connecting to output side of relays ............................................................ 6

6.2.2.1  Output signal powered by automation adapter .................................. 6
6.2.2.2  Output signal powered by alternate power supply ............................. 6

7.0  OPERATING A VGREEN

®

 MOTOR AUTOMATION ADAPTER ................................ 6

7.1  Adjusting motor speed ......................................................................................... 6

8.0  FAULT STATUS ........................................................................................................ 7
9.0  TROUBLESHOOTING GUIDE ................................................................................. 7
10.0 SPECIFICATIONS ..................................................................................................... 7

F O R M

VGreen

®

 Motor Automation Adapter Kit

Installation Manual and User’s Guide 

For use with Century

®

 VGreen variable speed motors

C0048E

Revised

December 2018

Regal Beloit America, Inc.

1325 Heil Quaker Blvd.

LaVergne, TN 37086

Customer Service: 1-800-262-6484

www.RegalBeloit.com

•  Read and follow all instructions carefully.
•  Disconnect and lock out power before installation and maintenance.  Working on or near energized equipment could result in severe 

injury or death.

1.0   KIT CONTENTS

Содержание VGreen

Страница 1: ...ing to input side of relays 5 6 2 2 Connecting to output side of relays 6 6 2 2 1 Output signal powered by automation adapter 6 6 2 2 2 Output signal powered by alternate power supply 6 7 0 OPERATING...

Страница 2: ...other products other than the automation adapter The following steps should be followed to connect the automation adapter to a VGreen motor 1 Disconnect all power sources from the motor and wait five...

Страница 3: ...Figure 8 Communication connector disconnected Figure 9 User interface and rubber gasket removed 7 Install the conduit fitting PN 2017587 002 turning until snug Figure 10 Conduit fitting installed 8 Ro...

Страница 4: ...mble the new metal terminal box cover two screws Plug the four user interface mounting holes with the plastic clips PN 2514059 001 Figure 15 Terminal box cover and clips installed Mounting Holes 4X 12...

Страница 5: ...e precautions could result in serious injury or death NOTE User may use a minimum of 1 and a maximum of 4 inputs to the automation adapter WARNING SHOCK HAZARD Failure to connect the automation adapte...

Страница 6: ...rovided turn the potentiometer clockwise or counterclockwise Clockwise increases the speed and counterclockwise decreases the speed The speed ranges from 600 3450 RPM Do this for each input When apply...

Страница 7: ...tor but power LED is not illuminated on the automation adapter Power supply cables are loose at the RS 485 connector Check tighten the connections Power supply cables are loose at CON 1 of the adapter...

Отзывы: